7
General Installation Process
12
Install Rack Handles
NOTE: Rack handles are required to install the bezel. For detailed
instructions, see the Service Guide.
13
Install Intel® RAID C600 Upgrade
Key (optional)
Locate the white 4-pin key header. Carefully pickup the Intel
®
RAID C600 Upgrade
Key. Match the Key and connector orientation and press down to install.
STOR_UPG_KEY
14
Install Intel® Remote Management Module 4 (optional)
Locate the RMM4 Lite connector, carefully
pickup the Intel
®
RMM4 Lite module,
match the alignment pin of the module
and the connector on server board, then
press to install.
Install Intel® RMM4 NIC
Install Intel® RMM4 Lite
A
Remove the filler Panel and Retention Device refer to
STEP 11
.
B
Connect one end of the flex cable
to the RMM4 connector on the
RMM4 NIC module.
C
Attach the RMM4 module with two screws as shown.
Fasten the bracket with one screw as shown.
D
E
Connect the opposite end of the
flex cable to the RMM4 connector
on the server board.
Note: The cable connectors are
keyed and can only go in one way.
RMM4
Lite
Connector
RMM4 NIC
Connector
B
Filler Panel
Retention Device
A
C
D
E
15
Install Intel® RAID Smart Battery (optional)
A
Position the battery against the side wall.
B
Align the tabs on the plastic battery holder with the mounting holes in the
chassis and slide the plastic battery holder toward the front of the system
until the tabs engage with the mounting holes.
A
B
Summary of Contents for R2000SC
Page 2: ...This page is intentionally left blank...
Page 19: ...This page is intentionally left blank...
Page 20: ...G71872 002...