Warning:
It is critical that both power trays have the same J7 jumper configuration. If the power trays are
configured differently, the power standby switch controls only one power tray. This can result in an
improper cooling scenario.
lists the configuration choices for the J7 jumpers.
Figure 15. Power Standby Switch Disable Jumper Locations
J7 Power Standby
Switch Bypass Jumper
Front
Table 3. Power Tray J7 Jumper Configurations
Power Tray 1 J7
Jumper
Power Tray 2 J7
Jumper
Power Standby
Switch
Installed
+
Installed
=
Enabled
Removed
+
Removed
=
Disabled
Installed
+
Removed
=
Invalid
Removed
+
Installed
=
Invalid