Intel® Compute Module MFS5000SI User Guide
27
7. Open both DIMM socket levers (see letter “A” in the following figure). Position the
DIMM above the socket, taking care to align the two small notches in the bottom of
the DIMM with the keys in the DIMM socket (see letter “B”). Insert the bottom edge
of the DIMM into the socket and press down on the top edge of the DIMM (see letter
“C”) until the DIMM is fully seated and the retaining clips (see letter “D”) are locked
firmly into place.
Important:
Visually check that each latch is fully closed and correctly engaged with
each DIMM edge slot.
Figure 30. Installing DIMMs
AF002453
A
C
D
B