Intel® Server System M50CYP1UR Family System Integration and Service Guide
73
6.4
Power Supply Replacement
Caution:
The power supply is only hot-swappable (system does not have to be powered down) if the system
is configured with two power supply modules operating in a 1+1 redundant configuration.
Systems with a single power supply installed or a system operating in a 2+0 non-redundant power mode,
MUST be powered OFF before removing the power supply module from the system.
Figure 81. Power Supply Removal
1.
Detach the power cord from the power supply to be removed.
2.
Push and hold the green latch in the direction shown (see Letter A).
3.
Use the handle to pull the power supply module from the system (see Letter B).
Figure 82. Power Supply Installation
4.
Locate the replacement power supply.
5.
Slide the power supply into the power supply bay until it clicks and locks in place (see Letter A).