Intel® Server System M20NTP1UR - System Integration and Service Guide
39
Note
: Cable colors in the diagram are for reference purposes only.
Figure 38. NVMe* Cable Kit Routing
Required Tools and Supplies
•
Intel cable accessory kit: : iPC -
NTPCBLSL104K
•
Anti-static wrist strap and conductive workbench pad (recommended)
•
Phillips* head screwdriver
1.
Power off the system and disconnect all cables from the back of the system.
2.
Remove the system top cover (see
Section 3.1.1
3.
Remove the Air Duct (see
Section 3.2.1
4.
Locate and unpack the cables from the cable kit
5.
Select a cable and attach it to the identified connectors from
. Repeat for each cable.
6.
Assemble and Install NVMe* SSDs into the front drive bay (See
Section 3.5
3.7
M.2 SSD Installation
The server board has support for one PCIe* M.2 SSD.
Required Tools and Supplies
•
PCIe* M.2 SSD
•
M.2 SSD Latch – Included with system
•
Anti-static wrist strap and conductive workbench pad (recommended)
•
Phillips* head screwdriver
1.
Power off the system and disconnect the power cable(s).
2.
Remove the system top cover (see
Section 3.1.1
).
3.
Remove the Air Duct (see
Section 3.2.1
4.
Summary of Contents for M20NTP1UR
Page 2: ...2 This page intentionally left blank...
Page 101: ...Intel Server System M20NTP1UR System Integration and Service Guide 101 1 2 3 4 5...
Page 102: ...Intel Server System M20NTP1UR System Integration and Service Guide 102 1 2 3 4 5 6 1 2 3...
Page 103: ...Intel Server System M20NTP1UR System Integration and Service Guide 103 1 2 3 4 5...
Page 112: ...Intel Server System M20NTP1UR System Integration and Service Guide 112 1 2 3 4 5 ESD 6 1 2 3...
Page 113: ...Intel Server System M20NTP1UR System Integration and Service Guide 113 1 2 3 4 5...