Intel® Storage Server System JBOD2000S3 Service Guide
21
Appendix A.
Technical Reference
Power Supply Input Voltages
460W power supply module
100 - 127 V at 50/60 Hz 5.8 A
200 - 240 V at 50/60 Hz 2.9 A
Power Supply Output Voltages
The following table lists the total wattage available from the power subsystem for each voltage. For
information about calculating the power usage for your configuration, use the Power Budget Tool.
Table 1. Power Supply Output Capability
Voltage
Maximum Current
12V
38.0A
12VSB
2.1A
System Environmental Specifications
The following table defines the system level operating and non-operating environmental limits.
Table 2. System Environmental Limits Summary
Parameter
Limits
Operating Temperature
+10°C to +35°C with the maximum rate of change not to exceed 10°C per hour
Non-Operating Temperature
-40°C to +70°C
Non-Operating Humidity
90%, non-condensing at 35°C
Acoustic noise
Sound power: 7.0 BA in operating condition at typical office ambient
temperature. (23 +/- 2°C)
Shock, operating
Half sine, 2 g peak, 11 milliseconds
Shock, unpackaged
Trapezoidal, 25 g, velocity change 136 inches/second (
≧
40 lbs to < 80 lbs)
Shock, packaged
Non-palletized free fall in height 24 inches (
≧
40 lbs to < 80 lbs)
Vibration, unpackaged
5 Hz to 500 Hz, 2.20 g RMS random
ESD
+/-12 KV except I/O port +/- 8 KV per Intel
®
Environmental test specification
System Cooling Requirement
in BTU/Hr
460 Watt Max – 1570 BTU/hour