14
Specification Update
BJ111
X
X
No Fix
VM Exits Due to “NMI-Window Exiting” May Not Occur Following a VM Entry to the
Shutdown State
BJ112
X
X
No Fix
Execution of INVVPID Outside 64-Bit Mode Cannot Invalidate Translations For 64-
Bit Linear Addresses
BJ113
X
X
No Fix
VEX.L is Not Ignored with VCVT*2SI Instructions
BJ114
X
X
No Fix
MCI_ADDR May be Incorrect For Cache Parity Errors
BJ115
X
X
No Fix
Instruction Fetches Page-Table Walks May be Made Speculatively to Uncacheable
Memory
BJ116
X
X
No Fix
Reported Maximum Memory Frequency Capability May Be Higher Than Expected
BJ117
X
X
No Fix
The Processor May Not Properly Execute Code Modified Using A Floating-Point
Store
BJ118
X
X
No Fix
Execution of GETSEC[SEXIT] May Cause a Debug Exception to be Lost
BJ119
X
X
No Fix
BJ120
X
X
No Fix
Specific Graphics Blitter Instructions May Result in Unpredictable Graphics
Controller Behavior
BJ121
X
X
No Fix
IA32_MC5_CTL2 is Not Cleared by a Warm Reset
BJ122
X
X
Plan Fix
Performance Monitor Counters May Produce Incorrect Results
BJ123
X
X
No Fix
The Corrected Error Count Overflow Bit in IA32_ MC0_STATUS is Not Updated
After a UC Error is Logged
BJ124
X
X
No Fix
VT-d Interrupts May Occur When the PFO Bit is Set
BJ125
X
X
No Fix
Processor May Livelock During On Demand Clock Modulation
BJ126
X
X
No Fix
The Upper 32 Bits of CR3 May be Incorrectly Used With 32-Bit Paging
BJ127
X
X
No Fix
EPT Violations May Report Bits 11:0 of Guest Linear Address Incorrectly
BJ128
X
X
No Fix
Errata (Sheet 5 of 5)
Number
Steppings
Status
ERRATA
D-2
Q-0
Specification Changes
Number
SPECIFICATION CHANGES
None for this revision of this specification update.
Specification Clarifications
Number
SPECIFICATION CLARIFICATIONS
None for this revision of this specification update.
Summary of Contents for BX80623G530