Table 1. Errata Summary
No.
Plans
Description of Errata
1.
Doc
IPMI over serial direct connect not supported.
2.
Fix
Serial over LAN and IPMI over LAN connections may terminate unexpectedly under certain conditions.
3.
Fix
Intermittent beep code 1-5-2-1 when booting with two processors.
4.
Doc
Power supply population errors may not appear in the SEL.
5.
Fix
Fan 5 may report a reading of 0 RPM after the BMC is updated.
6.
Fixed
The BMC may not respond to the IPMI command,
Send Message
sent via LAN.
7.
Fixed
Fans may take a long time to slow down after fan boosting.
8.
Fixed
System requires ~35 seconds after AC is power applied before the power button responds.
9.
Fix
SEL events for Hot-swap Controller (HSC) may appear after a DC cycle
10.
Fixed
Fans may run faster than expected after exiting BIOS setup.
11.
Fixed
System fault LED may report incorrect status for some events.
12.
Fixed
Fan removal does not generate a SEL event.
13.
Fix
Power supply redundancy state is misleading when only one power supply is installed.
14.
Fix
Hot-swap Controller (HSC) and Local Control Panel (LCP) updates may take a long time
15.
Fixed
Console Redirection Baud Rate Setting auto changing to 19.2K with Serial Over LAN (SOL) active.
16.
Fixed
Serial Over LAN (SOL) unable to redirect DOS output.
17.
No Fix Password on boot not supported.
18.
Fixed
Intel
®
Embedded Server RAID Technology II option is not enabled in the initial BIOS release.
19.
Fixed
HSC and BMC versions intermittently not seen in BIOS setup
20.
Fixed
Intel
®
Server Boards S5000PAL/S5000XAL and Intel
®
Server System SR1500AL show a “Changes in
Hardware or Drivers Detected” error message during WHQL ACPI stress testing.
21.
Fixed
POST LEDs do not turn off after operating system loads.
22.
Fixed
Checkup7.exe (microcode update utility) is not storing microcode in BIOS.
23.
Fixed
Intel
®
RAID Controller SRCSAS144E causes systems to reset multiple times before completing POST.
24.
Fixed
Change Logo Utility does not save modified BIOS capsule files with correct extension.
25.
Fixed
PS/2 keyboards and mice may stop functioning after Red Hat* Enterprise Linux is installed.