13

M L X   3 0 0   w a t t   X e n o n   L i g h t   s o u r c e 

ELECTROMAGNETIC COMPATIbILITY (EMC) USER INfORMATION

warning:  Medical electrical equipment needs special precautions regarding eMc and needs to be installed and 

put into service according to the electromagnetic compatibility [eMc] information provided in the accompanying 

documents.

warning:  Portable and Mobile rF communications equipment can affect Medical electrical equipment.

warning:  the equipment or system should not be used adjacent to or stacked with other equipment and that if 

adjacent or stacked use is necessary, the equipment or system should be observed to verify normal operation in the 

configuration in which it will be used.

note:  the eMc tables and other guidelines that are included in the instruction Manual provide information to the 

customer or user that is essential in determining the suitability of the equipment or system for the electromagnetic 

environment of use, and in managing the electromagnetic environment of use to permit the equipment or system to 

perform its intended use without disturbing other equipment and systems or non-medical electrical equipment.

table 201

Guidance and Manufacturer’s Declaration – Emissions All Equipment and Systems

the MLX light source is intended for use in the electromagnetic environment specified below.   

the customer or user of the MLX

 

light source should assure that it is used in such an environment.

emissions test

compliance

electromagnetic enforcement – guidance

rF emissions  

cisPr 11

group 1

the MLX unit uses rF energy only for its internal function.  therefore, its rF 

emissions are very low and are not likely to cause any interference in nearby 

electronic equipment.

rF emissions  

cisPr 11

class B

radiated and 

conducted 

emissions

 

the MLX unit is suitable for use in all establishments including domestic, and 

those directly connected to the public low-voltage power supply network that 

supplies buildings used for domestic purposes.

conducted emissions tests Performed at both 240Vac, 50hz and 120Vac, 

60hz

harmonics  

iec 61000-3-2

n/a

equipment intended for Professional use only

Flicker 

iec 61000-3-3

n/a

equipment intended for Professional use only

Summary of Contents for Luxtec MLX

Page 1: ...300 WATT XENON LIGHT SOURCE Operation and Service Manual ENGLISH 99 Hartwell Street West Boylston MA 01583 USA Tel 1 508 835 9700 US Toll Free 1 800 325 8966 Fax 1 508 835 9976 Website http www integra surgical com E mail custsvcluxtec integra surgical com ...

Page 2: ...4 Precautions 5 Overview 5 6 Operation 6 7 Xenon Lamp Module Replacement 8 Fuse Replacement 9 Optional Floor Stand Assembly 10 Replacement Parts and Accessories 10 Maintenance and Cleaning 11 Troubleshooting 12 Specifications 13 15 Electromagnetic Compatibility EMC User Information 16 Block Diagram 17 Repair and Return 17 Limited Warranty ...

Page 3: ...n o n l i g h t s o u r c e indication for use The Luxtec MLX light source is designed to supply high intensity white light to a fiber optic cable for illumination of a surgical field during a surgical and or medical procedure ...

Page 4: ...ure On Off Brightness Stand by Motor System Status Display Fan System CE Do Not Dispose Listed by ETL Push Listed by CSA Hours Part Number Over Temperature Batch Code Intensity Serial Number Authorized Representative in the Lamp European Community Manufacturer Keep dry or TABLE OF SYMBOLS Found on a medical grade light source other illumination related equipment fiber optic cables and correspondin...

Page 5: ...tion of the eye Use care not to point any fiber optic cable directly at the eye while operating the light source The light source produces high intensity light Thermal burns can result from improper use of the light source or from the light output of the fiber optic cable Take precautions to verify that the fiber optic cable is appropriately suited for the light source Xenon and other high illumin...

Page 6: ...e infrared IR filtered light The lamp is housed in a lamp module that can be easily serviced without special tools Set Up and Inspection Before Use The light source comes with the hospital grade power cord packaged separately Verify that both components are in good condition Before turning power on to the light source make sure the unit is plugged into any standard 100VAC to 240VAC 47 63Hz as appr...

Page 7: ...matically return to the light intensity reading after15 seconds 8 The system can be placed in stand by mode no light emitted allowing the surgeon to unplug a headlight and move around the table or to change cables in a laparoscopic or endoscopic procedure CAUTION Cable end fitting can be HOT NOTE If unit is left in stand by mode for 15 minutes it will automatically shut off the lamp Fans will keep...

Page 8: ... 2 Place the module into the light source 3 Seat module securely 4 Replace the lamp module door and secure it with the screw 5 Align top cover brackets into slots and slide forward 6 Slide the top plate forward until it engages the front panel 7 Replace the retaining screws in the rear panel 8 Replace the hospital grade power cord and turn on power to verify operation To Reset Lamp Age Meter 1 Usi...

Page 9: ... the back of the light source Using a small flat screwdriver pry open the retaining door Figure 8 and pry out the red plastic block from the power entry module Figure 9 Check to see if the fuse is blown if blown replace with a fuse of the same rating Luxtec P N 600987 or T6 3AL250 Replace the red block in the housing Snap the retaining door into place Plug cord back into light source and retest th...

Page 10: ... the Luxtec logo is properly aligned slide the handle onto the column and center the handle about 5 inches 13cm below the light source base plate Tighten handle screw to hold in place 2 Insert assembled column into the base Seat firmly 3 Attach the light source base onto the base plate Figure 10 with the four 4 screws provided using the Phillips head screwdriver provided 4 Secure the light source ...

Page 11: ...LX light source Optional Accessories AX2100BIF UltraLite Pro headlight with 9ft 275cm premium bifurcated cable Mark II module and gown clips AX2100BIFSL UltraLite Pro headlight with 9ft 275cm premium bifurcated cable Mark II module and gown clips with short linkage 001337 MLX Floorstand Allow unit to cool for at least 15 minutes prior to cleaning Unplug the power cord before cleaning The light sou...

Page 12: ...11 M L X 3 0 0 w at t x e n o n l i g h t s o u r c e TROUBLESHOOTING ...

Page 13: ...12 M L X 3 0 0 w at t x e n o n l i g h t s o u r c e SPECIFICATIONS ...

Page 14: ...ment of use to permit the Equipment or System to perform its intended use without disturbing other Equipment and Systems or non medical electrical equipment Table 201 Guidance and Manufacturer s Declaration Emissions All Equipment and Systems The MLX light source is intended for use in the electromagnetic environment specified below The customer or user of the MLX light source should assure that i...

Page 15: ...240VAC 50Hz and 120VAC 60Hz Surge IEC 61000 4 5 1kV Differential 2kV Common 1kV Differential 2kV Common Mains power quality should be that of a typical commercial or hospital environment Note Tests Performed at both 240VAC 50Hz and 120VAC 60Hz Voltage dips short interrup tions and voltage variations on power supply input lines IEC 61000 4 11 95 Dip for 0 5 Cycle 60 Dip for 5 Cycles 30 Dip for 25 C...

Page 16: ...mmended separation distance in meters Field strengths from fixed transmitters as determined by an electromagnetic site survey should be less that the compliance levels V1 and E1 Interference may occur in the vicinity of equipment containing a transmitter Table 206 Recommended Separation Distances Between Portable and Mobile RF Communications Equipment and the MLX Equipment and Systems that are NOT...

Page 17: ...16 M L X 3 0 0 w at t x e n o n l i g h t s o u r c e BLOCK DIAGRAM ...

Page 18: ...period due to any defect in workmanship or material F O B factory if 1 Customer promptly reports such defect to Luxtec in writing 2 If requested by Luxtec customer returns equipment to Luxtec with shipping charges and 3 Upon inspection Luxtec finds the equipment to be defective This warranty is contingent upon normal and proper use of the equipment It does not cover equipment that has been modifie...

Page 19: ...469 Rev B 01 10 www Integra Surgical com The Integra wave logo and Integra Surgical are trademarks of Integra LifeSciences Corporation Luxtec and UltraLite are registered trademark of Integra LifeSciences Corporation or its subsidiaries Copyright 2010 Integra LifeSciences Corporation All rights reserved ...

Reviews: