background image

 

 

2/3 

145951_V01_QSG_FLAMEBOY_EN.docx 

Fitting the nozzle for the gas in use 

 

The P80 nozzle for butane/propane gas is fitted ex-factory. If necessary, replace the nozzle. 

 

Type of gas  

Nominal and maximal  

gas input pressure 

Inscription nozzle 

Natural (>85 % methane) gas 

20 mbar 

N110 

 

 

 

Butane/propane gas 

50 mbar 

P80 

 

 

 

Town (methane, others) gas 

8 mbar 

M250 

 

 

 

Turn the gas flow control valve to have access to the brass screw (

b

). Remove the screw, turn over 

the device and allow the nozzle to drop out. Insert a new nozzle and retighten the brass screw. 

 

FLAMEBOY may only be operated with the nozzle that corresponds to the gas type in use. 

Inspect the O-ring in the brass screw for damage and, if necessary, replace it. 

 

Connection of an adapter 

 

 

When replacing the adapters, always close off the gas supply  and remove the gas 

cartridge.  

 

  Insert the appropriate adapter in the opening down on the handle (

g

). 

Make sure it audibly clicks into position.

 

 

 

  To remove the adapter, use a pointed tool to press the turquoise 

adapter latch (

d

) inward and pull out the adapter downwards. 

 

 

Connecting a gas cartridge 

 

 

The P80 nozzle and the gas cartridge adapter must be installed. Gas cartridges may only 

be used at 15

 .

C

°

 

5

3

Only replace a gas cartridge, if the adapter is connected to the 

device and closed.

 

    

 

CV360 cartridge adapter: 

  Hold the brass knurled wheel of the gas cartridge adapter and close 

the valve by unscrewing the black cap clockwise.  

  Press the gas cartridge into the cap until its audibly clicks into 

position. 

  Hold the brass knurled wheel and open the valve by screwing the 

black cap all the way in. 

EXPRESS 444 cartridge adapter: 

  Hold the brass knurled wheel and connect the gas cartridge by 

screwing it clockwise into the adapter. 

 

Connecting a tubing 

 

    

 

  Screw the threaded connector of the gas tubing onto the adapter and 

tighten it with a 17 mm fork wrench. 

Or: 

  Connect the end of the gas hose to the adapter and fix it with a 

tubing clamp.   

 

 