MP 01 CO ppm
50 *AV 33 CV
MP 01
MP 01.2 Ex %LEL
10 AV 13*CV
MP 01.1 CO ppm
50 *AV 33 CV
3.4
Menu Measuring Values
This menu is for displaying the current value (CV) or the average value (AV) with gas unit and gas type for each
active measuring point according to the defined mode of control (CV or AV mode). For gas type CO both values
are displayed together.
MP 01.
1
= Measured value of the bus transmitter with MP address 01.
MP 01.
2
= Measured value of the analog transmitter connected to the bus transmitter via MP address 01.
The MP address and the display depend on the installed software.
In the version without analog transmitters at the 4 to 20 mA input of the DT- 05 the addresses are listed from
MP-01 to MP 16.
In the version with additional analog transmitters the addresses are listed from 1 to 8 with the index XX.1 for the
measured value of the bus transmitter and with XX.2 for the measured value of the analog transmitter.
Display for software version 16 bus transmitters
--------------------------------------------------------------------------------------------------------------------------------------------
Display for software version 8 bus transmitters and 8 analog transmitters
--------------------------------------------------------------------------------------------------------------------------------------------
Symbol Description
Default Function
MP
01
.1 Measuring point No.
Bus transmitter with address 01
MP XX.
1
Measured value
Measured value bus transmitter at address XX
MP XX.
2
Measured value
Measured value analog transmitter at bus transmitter
with address XX
CO
Gas type
See 3.6.2
ppm
Gas unit
See 3.6.2
CV
Current value
Current value of gas concentration
AV
Average value
Average value (10 measured values within the time unit)
*
Control mode
Display of selected control mode (CV or AV)
Not active Status MP
MP not active
Error
Fault MP
Current signal < 3 mA or > 22 mA
MP 01
Specifications subject to change without notice. | USA 130917 | Page 9 of 22
12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.IN
TEC
| relevantsolutions.com/inteccontrols
DGC3 – UserManual
Polygard® is a registered trademark of MSR | DGC3
Specifications subject to change without notice. | USA 160104 | Page 9 of 22
12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.IN
TEC
| relevantsolutions.com/inteccontrols
DGC3 – UserManual
PolyGard
®
is a registered trademark of MSR-Electronic GmbH | DGC3
INTEC Controls | 12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.INTEC | inteccontrols.com
Specifications subject to change without notice. | USA 200211 | Page 9 of 22
DGC3 – UserManual