INSYS Modem 336/56k 4.1 (UL)
S
Registry
S13*
Number of dialing attempts to send the message
Bit
Meaning
Bit 0 – 3
Number of dialing attempts
Range of values: 1...12
Default value: 3
S13 determines the number of attempts to send the
message.
Note:
The limitation to a maximum of 12 at-
tempts is necessary for approval pur-
poses (black listing).
Bit 4 - 7
Reserved
S14*
General settings
Bit
Meaning
Bit 0
Reserved
Bit 1
Echo on inputs
Command echo
0: Echo off
1:
Echo
on
Bit 2
Reserved
Bit 3
Result format
Result codes:
0: Message numbers (
ATV0
)
1: Message texts (
ATV1
)
Bit 4
Reserved
Bit 5
Tone/pulse dialing
Tone/pulse
0: Tone dialing (
ATT
)
1: Pulse dialing (
ATP
)
Bit 6
Reserved
Bit 7
Originate/answer
Originate/answer 0:
Answer
mode
1: Originate mode
S15*
DTC Time Settings
The idle connection control is a function integrated in the firmware which moni-
tors the data transmission in online mode. This function prevents the modem to
stay online for an unlimited amount of time, although no data is being transmit-
ted anymore.
In the registry S15, any time period between 1 and 255 seconds may be entered. If
S15 is set to 0, the idle connection control is switched off.
The timer will run immediately after the modem goes off-hook. As soon as the
timer has run out, a modem reset is performed (which will forcibly lead to the
hanging up of the modem).
S17*
Initial character for remote configuration
In S17, the ASCII code of a character which is used to start the remote configura-
tion, is defined. Values >127 switch the remote configuration off completely. The
default setting in S17 is “42”, which equals the ASCII character “*”. This means
that the remote configuration is started with the Escape character sequence
<Pause> **** <Pause>
.
Note: The number of characters in the Escape sequence is fixed to “4” characters).
July 06
79