Functions
EBW-E100
76
12.5.6
Configuring an URL Filter
With the help of the URL filter, the proxy server can restrict possible URLs, which
can be accessed by computers from the internal network of the EBW-E100. This
will allow only access to URLs which are entered in the filter list. All other URLs are
blocked. To allow access to the Internet only via the proxy, the firewall must be ac-
tivated. Without the firewall, the access to any URLs would be possible just by by-
passing the proxy.
The IP address and the port of the proxy must be defined at the clients (e.g. a web
browser on a PC), which establish connections via the proxy.
Configuration via web interface (menu "Server services", page "Proxy")
In order to enable the URL filter, check the checkbox "Activate filter".
In order to enter an allowed URL, which is accessible from the internal
network, enter the desired URL in the entry field "Allowed URLs".
In order to delete an URL from the list, delete the text of the URL from
the list.
Save your settings by clicking "OK".
12.5.7
Configuring IPT
The EBW-E100 also allows data transfer via an IPT channel. It can act as IPT slave
here.
Configuration via web interface (menu "Server services", page "IPT")
In order to enable IPT, check the checkbox "Activate IPT slave".
In order to display the current state of the IPT slave, click on the link "IPT
current state".
In order to display the messages of the IPT slave, click on the link "IPT
log". This helps to draw conclusions on the failure cause in case of an
unsuccessful connection attempt.
In order to configure the connection to the IPT master, enter its IP
address or domain name into the entry field "IP address or domain
name". Enter the port on which the IPT master accepts the connection
into the entry field "Port". Enter the access data for registering at the IPT
master into the entry fields "User name" and "Password". These data
must be entered for the primary IPT master. A secondary IPT master can
be entered optionally that will be used following an unsuccessful
connection attempt to the primary IPT master.
In order to specify the IPT device identifier, enter it into the entry field
"IPT device identifier". By default, a combination of the string "INS" and
the MAC address of the EBW-E100 is entered.