TriggerLinc Owner’s Manual  

 

Page 7 of 12 

 

CONTROLLING INSTEON RESPONDERS FROM TRIGGERLINC 

Linking TriggerLinc to an INSTEON Responder 

In default mode, TriggerLinc will: 

 

Turn on Responders when it opens 

 

Turn off Responders when it closes  

This mode is ideal for garage doors, closets, sheds, etc., where you want the lights on when door/windows are 
opened and off when they are closed. If you require more flexible functionality, see 

Using TriggerLinc’s Multi-Scene 

Mode. 

 

To use TriggerLinc as an INSTEON Controller, follow these steps to Link TriggerLinc and an INSTEON Responder 
(the device you wish to control with TriggerLinc) together. Refer to the Responder’s Owner’s Manual for detailed 
instructions on how to properly install and Link it to TriggerLinc.  

The following will work for the most common INSTEON devices: 

1)  If using the default mode, ensure the TriggerLinc jumper is installed. If using Multi-Scene Mode, the jumper 

should be uninstalled (or removed). 

NOTE: When changing the jumper setting, the battery will need to be removed and then reinstalled for the new 
jumper setting to take effect. 

2)  At the Responder, set it to the state you wish to activate from TriggerLinc (turn it on if you wish it to be on or off if 

you wish it to be off when TriggerLinc activates the scene) 

3)  Set TriggerLinc to Linking Mode by pressing & holding the Set button for 3 seconds 

 

 

The TriggerLinc Status LED 

will 

begin blinking  

 

You will have 4 minutes to complete the next step before Linking Mode automatically times out.  

4)  Press & hold the Responder's Set button for 3 seconds 

 

 

The TriggerLinc Status LED 

will 

stop blinking and turn on solid   

5)  Confirm that Linking was successful by opening and closing the magnet/sensor  

  The 

Responder 

will 

respond appropriately 

6)  If you wish to Link multiple Responders to the same TriggerLinc, repeat steps 2-4 with each Responder

 

Unlinking an INSTEON Responder from TriggerLinc 

If you are no longer going to use an INSTEON Responder that has been Linked to TriggerLinc, it is very important 
that you Unlink it. Otherwise, TriggerLinc will retry any commands repetitively, thus slowing down the system.  

The following will work for the most common INSTEON devices: 

1) 

If the Responder is a multi-scene device, tap the Scene button you wish to remove control from until its LED 
illuminates  

2) 

Set TriggerLinc to Linking Mode by pressing & holding the Set button for 3 seconds  

The TriggerLinc Status LED 

will 

begin blinking  

3) 

Set TriggerLinc to Unlinking Mode by pressing & holding the Set button for 3 seconds again  

The TriggerLinc Status LED 

will 

continue blinking 

 

You will have 4 minutes to complete the next step before Unlinking Mode automatically times out.  

4) 

Press & hold the Responder’s Set button for 3 seconds 

The TriggerLinc Status LED 

will 

stop blinking and turn on solid 

 

5) 

Confirm that Unlinking was successful by opening and closing the magnet/sensor  

The Responder 

will 

no longer respond 

NOTE: If you are using Multi-Scene Mode, devices Linked to Scene 2 will not respond when the Set button on 
TriggerLinc is tapped. 

 

Summary of Contents for TriggerLinc 2843-2

Page 1: ...TriggerLinc INSTEON Wireless Door Window Sensor Open Close Model 2843 2...

Page 2: ...m TriggerLinc 7 Using TriggerLinc s Multi Scene Mode 8 CREATING INSTEON SCENES 9 ADVANCED FEATURES 9 Advanced Use of External Sensors with TriggerLinc 9 Restoring Power to TriggerLinc 9 Resetting Trig...

Page 3: ...Links to other INSTEON devices in minutes Operates via radio frequency RF to eliminate unsightly and inconvenient wiring Battery operated for easy installation Wires standard security sensors to Trig...

Page 4: ...ther In an INSTEON network every INSTEON device also acts as a repeater receiving and sending every message to all other devices in the network So by integrating more INSTEON devices you will strength...

Page 5: ...on Used to Link to other INSTEON devices Responders Control Linked Responders Scene 1 tap to toggle between on and off External Sensor Terminals When using an external sensor TriggerLinc is in the clo...

Page 6: ...Depending on the style of your door or window frame you might need to use some double stick tape beneath one of the pieces to ensure they are at the same relative height NOTE The included double stic...

Page 7: ...ve 4 minutes to complete the next step before Linking Mode automatically times out 4 Press hold the Responder s Set button for 3 seconds The TriggerLinc Status LED will stop blinking and turn on solid...

Page 8: ...d 4 Move the TriggerLinc magnet close to the main case putting it in the closed state The TriggerLinc Status LED will flash once 5 Link the desired Responders for when TriggerLinc opens Scene 2 Scene...

Page 9: ...ations note the TriggerLinc behavior it is assumed in this example that the TriggerLinc internal reed switch is not being used Several sensors connected in series TriggerLinc will show open if any of...

Page 10: ...between the two phases via RF Dual band INSTEON devices embody the full potential of a true INSTEON mesh network Taking the power line band signal and working in conjunction with the RF band signal i...

Page 11: ...les aux appareils radio exempts de licence L exploitation est autorise aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout...

Page 12: ...her oral or written express or implied including any warranty or merchantability or fitness for a particular purpose Any implied warranty including any warranty of merchantability or fitness for a par...

Reviews: