Quick-Start Guide                                                               INSTEON OutletLinc Dimmer (Dual-Band) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

*Setup Modes will automatically time out after 4 minutes. 
 

Using OutletLinc as a Responder

 

1) 

Make sure the load is on. If the load is not on, unplug it from OutletLinc and then plug it back in.  

The load should turn on and the OutletLinc Status LED should turn on solid green

 

2) 

Set the Controller to Linking Mode*. (For most Controllers, press & hold an On or Scene button for 10 seconds or the 
Set button for 3 seconds.) 

3) 

Press & hold the Set button on OutletLinc until it double-beeps (3 seconds) 

The OutletLinc Status LED should flash once, and then turn on solid green  

4) 

Confirm that Linking was successful by tapping the button you just Linked to on the Controller  

OutletLinc should respond appropriately 

 

Using OutletLinc as a Phase Bridger 

OutletLinc can help bridge the phases in your home and allow RF-only devices access to power line-only devices. For 
the best INSTEON network performance, it is recommended that you install at least two dual-band INSTEON devices. 
Search for dual-band INSTEON devices at: 

www.smarthome.com/dualband.  

 
Use the following procedure to test that the phases have been bridged: 
1)  Install additional dual-band INSTEON devices if they aren’t already installed  
2)  Start Phase Bridging Detection Mode* by tapping the Set button on OutletLinc four times quickly 

OutletLinc should begin beeping and the LED should be solid green 
The load may turn on or flash  

3)  Check the LED behavior of the other dual-band devices to see if they are on the opposite phase  

If at least one of the other dual-band device LEDs is blinking green, or is bright solid white or blue, the device is 
on the opposite phase. Continue to step 4. 

 

If none of the other dual-band devices exhibit the behavior above, they are on the same phase. Try one or both 
of the following: 

  Follow steps 2 and 3 with the other dual-band devices to see if they are bridging the phases 

  Move a dual-band device to another location until it exhibits the desired behavior  

4)  Tap the Set button on OutletLinc to exit Phase Bridging Detection Mode  

OutletLinc should stop beeping and the Status LED should remain solid green if the load is on or turn solid red 
if it is off 

 

Complete Instructions, Troubleshooting, and Tech Support 

Owner’s Manual:

 

http://wiki.smarthome.com/index.php?title=2472D_Manual

 

Call: INSTEON Gold Support Line at 800-762-7845 

CAUTION for the Dimmer Outlet 

CAUTION - To reduce the risk of overheating and possible damage to other equipment do not install to control a receptacle, a motor-operated appliance, a fluorescent 
lighting fixture, or a transformer-supplied appliance.  
Gradateurs commandant une lampe a filament de tungstene – afin de reduire le risque de surchauffe et la possibilite d’endommagement a d’autres materiels, ne pas 
installer pour commander une prise, un appareil a moteur, une lampe flourescente ou un appareil alimente par un transformateur. 

FCC Compliance Statement  

This device complies with FCC Rules Part 15. Operation is subject to two conditions: 
(1) This device may not cause harmful interference, and 
(2) This device must accept any interference that may be received or that may cause undesired operation. The digital circuitry of this device has been tested and found to 
comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful 
interference in residential installations. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the 
instructions, may cause harmful interference to radio and television reception. However, there is no guarantee that interference will not occur in a particular installation. If 
this device does cause such interference, which can be verified by turning the device off and on, the user is encouraged to eliminate the interference by one or more of the 
following measures: 

 

Re-orient or re-locate the receiving antenna of the device experiencing the interference. 

 

Increase the distance between this device and the receiver. 

 

Connect the device to an AC outlet on a circuit different from the one that supplies power to the receiver. 

 

Consult the dealer or an experienced radio/TV technician. 

WARNING! Changes or modifications to this device not expressly approved by the party responsible for compliance could void the user's authority to operate the 
equipment. 
 
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause 
interference, and (2) this device must accept any interference, including interference that may cause undesired operation of that device.  
Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions 
suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est 
susceptible d'en compromettre le fonctionnement.

Reviews: