About Local Programming

Local Programming Features

Linking Mode Readies the module for linking to another Insteon device. As linking is directional, the first 

device placed into linking mode will become the controller in the controller/responder 

relationship. The second device will become the responder. The device automatically exits 

linking mode after a link has been made with another Insteon device or four minutes have 

elapsed without linking.

Multi-Linking 

Mode

Readies the module for linking to multiple Insteon devices. The module will remain in linking 

mode for 4 minutes or until the module’s set button is tapped. This mode is very usefully for 

manually creating scenes.

Unlinking 

Mode

Allows the removal of links from the Insteon device. The device will automatically exit 

unlinking mode after a link has been removed from another Insteon device or four minutes 

have elapsed without linking.

Multi-

Unlinking 

Mode

Allows the removal of multiple links from the Insteon device. The device will stay in unlinking 

mode for 4 minutes or until the device’s set button is tapped.

To move right, press and 

hold the set button
To move down, tap the set 

button

Status LED blinks green

Status LED double-blinks 

green

Status LED blinks red

Status LED double-blinks 

red

The Local Programming Flowchart is a visual 

representation of the device’s settings. Many 

device features can be configured using this 

diagram. Some devices have more options 

than others but the Local Programming 

Flowchart presents even the most 

complicated devices with a straightforward, 

navigable path.

If using the Insteon Hub or any other central 

controller, it is strongly advised that you 

not use Local Programming. Your central 

controller can manage the device properties 

and links for you.

Navigation 

Local Programming

Using a Central Controller 

NEW

X

Summary of Contents for 2867-222

Page 1: ...Alert Module Owner s Manual Alert Module Owner s Manual ...

Page 2: ...stallation Alert Types 5 Triggering Alert Module from an Insteon Device 6 Local Programming About Local Programming 8 Local Programming Flow Chart 9 Factory Reset Factory Reset 11 Appendix Specifications 13 Troubleshooting 15 Certifications and Warnings 16 Product Warranty 17 ...

Page 3: ...3 Everything you need to quickly get up and running Getting Started Everything you need to quickly get up and running Getting Started ...

Page 4: ... Buttons Device Overview Insteon Alert Module Set Button Alert Speaker Status LED Armed Disarmed Plug Alert Module into an unswitched wall outlet Set Button See sections on Local Programming for set button functions ...

Page 5: ...oud Ringing Loud ringing will sound the moment Alert Module is triggered The loud ringing will persist for 30 seconds unless stopped by disarming Alert Module Alert Types Alert Module features two types of audible alerts Choose the suitable alert when creating a Scene using tap tap linking ...

Page 6: ...rt Module tap the set button until you hear the desired alert tone 2 On your Insteon device press and hold the set button until its LED begins blinking 3 On Alert Module press and hold the set button until you hear a double beep 4 Test Alert Module by triggering your sensor or turning on your Insteon device ...

Page 7: ...7 Use the local programming to link Insteon devices together with the set button Local Programming Use local programming to link Insteon devices together with the set button Local Programming ...

Page 8: ...nk has been removed from another Insteon device or four minutes have elapsed without linking Multi Unlinking Mode Allows the removal of multiple links from the Insteon device The device will stay in unlinking mode for 4 minutes or until the device s set button is tapped To move right press and hold the set button To move down tap the set button Status LED blinks green Status LED double blinks gree...

Page 9: ...me Instant Loud Ringing Tap Tap Tap Tap Tap Tap Press Press Press Press Unlinking Mode Multi Unlinking Mode Select Linking Mode Multi Linking Mode Select Press Tap Tap Press Press Tap Tap Exit Exit Exit Exit Local Programming Flow Chart Press Exit ...

Page 10: ...ill erase all links stored in the device s database as well as any customized properties Factory Reset A factory reset will erase all links stored in the device s database as well as any customized properties Factory Reset ...

Page 11: ...ry Reset 1 Unplug Alert Module from its power outlet 2 Simultaneously press and hold the set button while reconnecting Alert Module to power 3 Continue holding the set button until Alert Module stops beeping 4 When the reset is complete Alert Module will double beep ...

Page 12: ...12 Everything else you might need to know about your Insteon product Appendix Everything else you might need to know about your Insteon product Appendix ...

Page 13: ...udio Alert Beeper Setup Memory Non volatile EEPROM Status LED Red Green LED Insteon Features Insteon Device Category 0x07 Insteon Device Subcategory 0x1A Insteon ID 1 Insteon Links 400 Insteon Messages Repeated Yes Insteon Minimum Receive Level 10 mV Insteon Minimum Transmit Level 3 2 Vpp into 5 Ohms Insteon Powerline Device Yes Insteon Powerline Frequency 131 65 KHz Insteon RF Device Yes Maximum ...

Page 14: ... 26 6mm D Enclosure Material UV stabilized plastic Mounting Ungrounded polarized electrical outlet NEMA 1 15 Operating Environment Indoors Operating Humidity Range 0 85 relative humidity non condensing Operating Temperature Range 32º to 104º F 0º to 40º C Set Button Yes Storage Temperature Range 4º to 158º F 20º to 70º C Weight 3 3 oz Electrical Pass through Outlet No Power Consumption 0 75 Watts ...

Page 15: ...15 Troubleshooting For detailed troubleshooting information visit insteon com support ...

Page 16: ...r of the load device does not recommend dimming use a non dimming Insteon device USER ASSUMES ALL RISKS ASSOCIATED WITH DIMMING AN INDUCTIVE LOAD This device complies with FCC Rules and Industry Canada license exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference including interfere...

Page 17: ...nties whether oral or written express or implied including any warranty or merchantability or fitness for a particular purpose Any implied warranty including any warranty of merchantability or fitness for a particular purpose which may not be disclaimed or supplanted as provided above shall be limited to the two year of the express warranty above No other representation or claim of any nature by a...

Reviews: