IMPORTANT NOTE: In daily use you may use the boiler as soon as the water font button illuminates RED - BUT  ON FIRST

INSTALLATION YOU SHOULD WAIT AT LEAST 10 MINUTES BEFORE STARTING TO USE THE WATER.

• Your machine will not fill completely at once. The water input is electronically controlled to obtain maximum output, 

temperature and efficiency.

IN DAILY USE - switch on and wait for the water font push-button to illuminate RED, The water will then be at the correct

Temperature.

• To dispense hot water, place cup on drip-tray and press button.

7.0 - PROGRAM MODE

The LCD display in conjunction with the On/Off button gives access to the program menu which allows various settings to

be selected.

Most of the menus should not be accessed or changed because they are factory set, however, water volume (measured

vend) will need to be set, according to the cup-size and possibly water temperature may require alteration from factory

default setting.

To access the program menu:

• Switch the boiler off and back on again - within a few seconds of the boiler being switched on again, press and

hold the On/Off button in for approximately 10 seconds, until the display reads 

“PROGRAM MODE”

.

• Continue to press On/Off button to proceed through menu selections until desired mode is reached.

• To select mode, hold button for 3 seconds.

PROGRAM MEASURED WATER VOLUME (VEND/F1):

Enter PROGRAM MODE as described above. Scroll through the menu until “PROGRAM VEND H/F1” is displayed - hold

button  in  for  3  seconds  to  select.  Display  will  read  “VEND  H/F1”  and  number  of  seconds.  Using  the  On/Off  button  to

increase the number of seconds, and the Eco button to decrease the number of seconds, set the Vend Time as desired.

When set, hold button in for 3 seconds to confirm. Continue scrolling through menu until “EXIT PROGRAM” is displayed -

push and hold button for 3 seconds to exit.

UCD47-2 (Two x Water Fonts) ONLY:

The UCD47-2 boiler is supplied with two independant water fonts, each of which can be set to deliver a different measured

volume.  Set  the  first  water  font  (VEND  H/F1)  as  already  described  above  then  scroll  through  the  menu  to  the  next

selection (VEND C/F2). Repeat the instructions as above to set measured volume of second water font.

PROGRAM “ON DEMAND” WATER DISPENSE:

If preferred the water font can be configured to dispense water “on demand” instead of pre-set measured volumes:

Enter 

“PROGRAM MODE”

as described above. Scroll through menu until 

“PROGRAM VEND H/F1”

is displayed - hold

button in for 3 seconds to select. Display will read 

“VEND H/F1”

and number of seconds. Push the 

ECO

button to reduce

the number of seconds... continue pressing button until the display shows ZERO seconds (0.00) - hold button in for 3

seconds  to  confirm.

“EXIT  PROGRAM”

as  above. The  boiler  will  now  dispense  “on-demand”  e.g.  push  and  hold  the

button until desired volume of water has filled cup.

PROGRAM TEMPERATURE:

The boiler temperature is factory set to operate at around 97°C. This temperature can be adjusted in 1°C increments

between 80° and 99°C. Follow instructions as above, scrolling through menu until 

“TEMP SET”

is reached - hold button

down for 3 seconds to select. Continue pushing button until desired temperature is displayed - push and hold button in for

3 seconds to set temperature. Continue to scroll through menu until 

“PROGRAM EXIT”

is displayed - again push and hold

button for 3 seconds to exit program mode.

OTHER PROGRAM MENU OPTIONS:

NOTE: These are factory-set and generally do not need to be changed:

•  M/C  TYPE

-  This  allows  the  machine  to  be  set  between  “under-counter”  (UCDB  series)  and  “counter-top”  models.

(Factory-set to: under-counter). This would only need to be accessed if a new circuit board were fitted to the boiler.

• DRAIN TIME

- This is the time (in seconds) that the machine allows for the water (contained in water feed tube) to drain

back  from  the  water  font  (factory-set  at  3  seconds).  This  would  only  require  adjustment  if  the  counter-top  font  were

located more than 1 metre from the under-counter unit.

Summary of Contents for UCD12

Page 1: ...UCD SERIES UNDER COUNTER PUSH BUTTON DISPENSER INSTALLATION USER INSTRUCTION MANUAL IB24 ...

Page 2: ...es near boiling water During normal use of the boiler all surfaces remain cool However care should be taken to avoid potential injury from burns and scalding whilst dispensing water from the font Scale formation within the hot water appliances can be problematic in hard water areas Damage to the appliance caused by excessive scale build up may invalidate the warranty See notes on de scaling ENVIRO...

Page 3: ...Time from Cold 33 Minutes to full boiler capacity Model Ref No UCD47 UCD47 D 4 5kw standard configuration Description Under counter push button dispense Boiler Voltage 220 240v Single phase 50Hz Supply AC Rated Input 4 5kW standard configuration Output Amps 20A Fill Type Automatic Max Rapid Draw Off 47 Litres 235 x 200ml 7oz cups Recovery per Minute 0 75 Litres Temperature Adjustable between 80 95...

Page 4: ... away from underside of counter top A set of two ventilation grill pannels made from brushed stainless steel c w fixing screws is available from Instanta spares dept Part No UCVENT1 MAINS WATER CONNECTION Your machine has been supplied with a WRAS approved non toxic hose for connection to a suitable drinking water supply The water supply must have a pressure not exceeding 7bar 96psi and no lower t...

Page 5: ...provide protection from flooding ELECTRICAL CONNECTION UCD7 and UCD12 3 0kw MODELS Your machine is supplied with a standard 3 pin bonded plug and lead with 13amp fuse UCD47 4 5kw Standard Configuration suitable for 20amp supply Your machine is supplied with a 2mtr long electrical cord 3 x 2 5mm for connection to a suitable 20A single phase electrical supply via an isolation switch Optional Configu...

Page 6: ...47 2 boiler is supplied with two independant water fonts each of which can be set to deliver a different measured volume Set the first water font VEND H F1 as already described above then scroll through the menu to the next selection VEND C F2 Repeat the instructions as above to set measured volume of second water font PROGRAM ON DEMAND WATER DISPENSE If preferred the water font can be configured ...

Page 7: ...with an intelligent fault diagnosis system There are two levels of diagnosis 1 Simple Warnings accompanied by the illumination of a red exclamation mark Your boiler will continue to operate as normal whilst displaying these warnings 2 Critical Faults accompanied by the illumination of a red spanner Simple Warnings 1 The following messages may be seen The display will alternate between the boiler s...

Page 8: ...resolve the fault the boiler has overfilled This may have been caused by a faulty water inlet valve or very high or low incoming water pressure Consult with your supplier or phone Instanta service department on 01704 502911 or if this number is engaged 01704 501114 10 0 CLEANING The external surfaces of the water font can be kept clean by wiping with a damp cloth Do not use abrasive material on th...