5.0 - INSTALLATION

IMPORTANT:

If unit is being situated within a closed space (e.g. a cupboard), ensure there is sufficient ventilation and

adequate  airflow  to  prevent  overheating.  In  addition,  direct  the  air-vent  outlet  to  a  permanent  waste  (or  evaporation

container, if no permanent drain), away from the underside of the counter top - see drawing above.

Cut holes in counter using paper template provided - for hole positions.

Locate font into the prepared counter top and seal between the underside of the font and counter using a thin 

bead of silicone sealant or similar.

Secure  using  2  x  M8  nuts  and  washers  (supplied). 

IMPORTANT:

Ensure  electrical  plug/lead  from  font  is  not 

trapped when fixing water font to counter-top.

Fit drain kit (supplied) into font drip-tray. Using suitable flexible tube, direct to a permanent drain/waste.

Locate under-counter boiler unti beneath the water font (or within 1 mtr of it). Cut rubber hot water pipe to size (if 

too long) and connect to brass coupling in lid of under-counter unit (marked “HOT WATER [OUT] TO FONT”). 

Secure using plastic hose clip supplied.

Plug electrical lead into socket on lid of under-counter unit (marked: “FONT CONTROL”).

Push silicone rubber vent tube onto lid vent (see above) and direct to permanent waste (or evaporation container) 

away from underside of counter top.

A set of two ventilation grill pannels made from brushed stainless steel, c/w fixing screws, is available from Instanta 

spares dept. (Part No: UCVENT1).

MAINS WATER CONNECTION

Your machine has been supplied with a WRAS approved non-toxic hose for connection to a suitable drinking water 

supply. The water supply must have a pressure not exceeding 7bar (96psi) and no lower than 2bar (28psi).

• If your water pressure exceeds 7 bar, a suitable pressure reduction valve may need to be fitted to the water 

supply to bring the pressure to a level that the machine can cope with.

• In the unlikely event of the pressure being too low a booster pump can be supplied.

INSTANTA  CANNOT  BE  HELD  RESPONSIBLE  FOR  ANY  MACHINE  MALFUNCTION  IF  THE  WATER  PRESSURE

EXCEEDS THAT STATED. IF IN DOUBT, CONSULT YOUR WATER SUPPLY COMPANY.

The hose supplied with the machine is manufactured from materials which have been approved for drinking water and

should only be connected to a cold water supply.

Ventilation grill in

base of cupboard

Holes drilled in

base of cupboard,

to allow air flow

Permanent waste

Silicone rubber vent

tube, directed to

permanent waste

(or evaporation

container), away

from underside of

counter-top.

Lid vent

Seal between underside

of font and counter-top

using a thin bead of

silicone sealant

Ventilation pannel

Hot water transfer

tube [1mtr]. Cut any

surplus length off

tube, so that water

has a direct route to

the font

Plug-in font

control lead.

Summary of Contents for UCD12

Page 1: ...UCD SERIES UNDER COUNTER PUSH BUTTON DISPENSER INSTALLATION USER INSTRUCTION MANUAL IB24 ...

Page 2: ...es near boiling water During normal use of the boiler all surfaces remain cool However care should be taken to avoid potential injury from burns and scalding whilst dispensing water from the font Scale formation within the hot water appliances can be problematic in hard water areas Damage to the appliance caused by excessive scale build up may invalidate the warranty See notes on de scaling ENVIRO...

Page 3: ...Time from Cold 33 Minutes to full boiler capacity Model Ref No UCD47 UCD47 D 4 5kw standard configuration Description Under counter push button dispense Boiler Voltage 220 240v Single phase 50Hz Supply AC Rated Input 4 5kW standard configuration Output Amps 20A Fill Type Automatic Max Rapid Draw Off 47 Litres 235 x 200ml 7oz cups Recovery per Minute 0 75 Litres Temperature Adjustable between 80 95...

Page 4: ... away from underside of counter top A set of two ventilation grill pannels made from brushed stainless steel c w fixing screws is available from Instanta spares dept Part No UCVENT1 MAINS WATER CONNECTION Your machine has been supplied with a WRAS approved non toxic hose for connection to a suitable drinking water supply The water supply must have a pressure not exceeding 7bar 96psi and no lower t...

Page 5: ...provide protection from flooding ELECTRICAL CONNECTION UCD7 and UCD12 3 0kw MODELS Your machine is supplied with a standard 3 pin bonded plug and lead with 13amp fuse UCD47 4 5kw Standard Configuration suitable for 20amp supply Your machine is supplied with a 2mtr long electrical cord 3 x 2 5mm for connection to a suitable 20A single phase electrical supply via an isolation switch Optional Configu...

Page 6: ...47 2 boiler is supplied with two independant water fonts each of which can be set to deliver a different measured volume Set the first water font VEND H F1 as already described above then scroll through the menu to the next selection VEND C F2 Repeat the instructions as above to set measured volume of second water font PROGRAM ON DEMAND WATER DISPENSE If preferred the water font can be configured ...

Page 7: ...with an intelligent fault diagnosis system There are two levels of diagnosis 1 Simple Warnings accompanied by the illumination of a red exclamation mark Your boiler will continue to operate as normal whilst displaying these warnings 2 Critical Faults accompanied by the illumination of a red spanner Simple Warnings 1 The following messages may be seen The display will alternate between the boiler s...

Page 8: ...resolve the fault the boiler has overfilled This may have been caused by a faulty water inlet valve or very high or low incoming water pressure Consult with your supplier or phone Instanta service department on 01704 502911 or if this number is engaged 01704 501114 10 0 CLEANING The external surfaces of the water font can be kept clean by wiping with a damp cloth Do not use abrasive material on th...

Reviews: