If the water pressure exceeds 7 bar a suitable water 
pressure reducing valve will need to be fitted to the 
water supply to bring it to a level that the machine 
can cope with. 

Failure to do so could result in 

the boiler overfilling.

   

The manufacturers cannot be held responsible 
for any machine malfunction if the water pressure 
is not within the range stated. If in doubt, consult 
your water supply company. 

*To meet WRAS installation requirements, an 
approved single-check valve providing back-flow 
prevention protection, should be fitted at the point 
of connection between the water supply and the 
appliances.

NOTE: Water that has been treated by the Reverse 
Osmosis process can become aggressive (due to 
lack of minerals or Ions), and in extreme cases can 
cause leaching and corrosion of pipes, fittings and 
other metal parts within the appliance.

If the appliance is being fed by water treated by 
Reverse Osmosis, we strongly recommend that the 
water is tested regularly.

If you have any queries in this respect, please contact 
our customer services team.

•  Connect to a suitable cold water drinking  
 

supply using 15mm copper pipe and using  

 

15mm straight push-fit coupling supplied.  

•  Push the 15mm coupling firmly onto the water  
 

inlet solenoid pipe. 

•  Push the 15mm cold water supply firmly into  
 

the bottom of the fitting.

Alternative Rear Entry Installation (Water 
Connection):

 

Replace 15mm straight coupling 

(supplied), with a 15mm push-fit elbow instead 
(available from plumber’s merchants). Push elbow 
firmly onto inlet solenoid pipe with the right angle 
facing the wall. Push the 15mm cold water supply 
firmly into the fitting.  

NOTE: To avoid damage to the appliance, do not use 
any solder connections whilst pipes are connected to 
the boiler.

•  A 15mm stop valve must be fitted between  
 

the water supply and the boiler so that it can  

 

be isolated.       

•  Water purification filters are available from  
 

Instanta to ensure fresh tasting water. In hard  

 

water areas, scale can cause problems.  

 

Fitting a scale reducer will help minimise scale    

 

but will not eliminate scale completely.

WE REGRET THAT INSTANTA CANNOT BE HELD 
RESPONSIBLE FOR SCALE RELATED PROBLEMS 
IF A SCALE REDUCER HAS BEEN INSTALLED

 

 

d) OVERFLOW/DRAIN

The fitting kit includes a second 15mm, straight 
push-fit coupling with a small piece of 15mm copper 
pipe pushed into it. 

This connector must be 

pushed onto the corresponding brass overflow 
connection on the services-bracket (along side 
the solenoid). 

If the overflow is to be extended, remove the copper 
pipe (supplied) and replace with 15mm pipe of your 
chosen length. The pipe must have a continuous fall 
and should not be longer than 300mm (if a longer run 
is required, use 22mm pipe to avoid airlocks.  
 
 
The overflow pipe should have no more than four 
right angle bends and should discharge to a safe, 
visible position.

Alternative Rear Entry Installation (Overflow/Drain): 
If rear entry has been chosen, the straight push-on 
coupling must be replaced with a 15mm push-fit 
elbow (available from plumber’s merchants).  
Push the elbow onto the brass overflow connection 
on the services-bracket (alongside the solenoid).  
As described above, the pipe must have a  
continuous fall etc. 

Under certain conditions the overflow pipe 
could vent steam, hot water or cold water. 
The manufacturers cannot be held responsible for 
property damage caused by flooding, because of 
a failure to direct the overflow-outlet to a suitable 
position where water can discharge safely to a 
waste or drain. 

If in all circumstances, it is absolutely not possible 
to direct the boiler overflow-outlet to a suitable 
position where overflowing water can run away 
safely, then the mains water supply to the boiler 
should be isolated and the unit switched off 
whenever it is left unattended for long periods 
(e.g. overnight).

VENT PIPE:

A small silicone rubber tube connects the tank-lid to 
the back panel. Ensure this is connected (and hasn’t 
come off in transit) and that the outlet fitting in the 
back-panel is not obstructed.

e) FITTING CASE

•  Attach the Earth wire connection to bottom  
 

of stainless steel boiler-case using M4 screw   

 

& washer supplied.  

4

5

Summary of Contents for SureFlow Series

Page 1: ...The Professional s Choice SureFlow Wall Mount Series WMS2 WMS5 WMS10 WA2N WA5N WA10N Auto Fill Wall mount Catering Water Boilers Installation And User Instructions...

Page 2: ...SUPPORT GUARANTEE 7 SERVICE WARNINGS FAULT DIAGNOSTICS 7 8 Introduction Dear Customer Congratulations on the purchase of your Instanta machine Your new water boiler is designed to give you years of tr...

Page 3: ...d Always disconnect the unit from the power supply before servicing Keep these instructions in a safe place for future reference Environmental Information Information on Disposal for Users of Waste El...

Page 4: ...lified electrician should carry out this work BASE ENTRY OF CABLE Use the cable gland Loosen cable gripping nut and pass cable through gland leaving enough free cable to connect to terminal block Tigh...

Page 5: ...can cause problems Fitting a scale reducer will help minimise scale but will not eliminate scale completely WE REGRET THAT INSTANTA CANNOT BE HELD RESPONSIBLE FOR SCALE RELATED PROBLEMS IF A SCALE RE...

Page 6: ...to use 2 Dispense water using the lever tap on the front of the appliance Safety Caution Use with caution as the boiler dispenses near boiling water Cleaning The external surfaces of the machine can b...

Page 7: ...iagnostics The boiler is fitted with an intelligent fault diagnosing system and can detect certain fault conditions as follows FILLING Flashing The white FILLING lamp flashes to indicate water starvat...

Page 8: ...ed or green or red and green If the problem reoccurs contact the Instanta Service Department 01704 502911 Dripping Taps These components are subject to wear tear but in the event of a tap failing with...