background image

 

 

 

1. Overview 

1.1 Description of Console (P/N: IC3000V01) 

 

TOP VIEW 

 

 
 
 
 
 
 
 
 

 

 

1. 

EMERGENCY button 

2. 

NURSE button 

3. 

CANCEL button 

4. 

Volume Control 

5. 

Microphone 

6. 

POWER LED 

7. 

STATUS LED 

8. 

Speaker 

 

REAR VIEW 

 

 

 

 

 

 

9. 

Line in jack (plug into tel. wall jack) 

10. 

Phone jack (plug into user’s tel.) 

11. 

USB Port (for programming only) 

 

 

BOTTOM VIEW 

 

12. 

Backup battery switch 

 

Locating a suitable position for the Console.

 

 

The  console  should  be  placed  on  a  flat  surface 
such as a countertop or table, and located in an 
area that is easily accessible. 

 

The  console  requires  main  power  and  a 
constant telephone connection. 

 

The  console  should  be  located  in  the  same 
room as the telephone jack it is connected to. 

 

The  console  should  not  be  placed  in  a  damp 
location such as a bathroom. 

 

The  console  should  not  be  placed  close  to  any 
heat source, such as direct sunlight, microwave 
oven, which can reduce signal strength. 

 

The  console  should  not  be  located  alongside 
other  radio  transmitting  devices  such  as  a 
mobile  phone,  cordless  phone,  or  wireless 
computer network (Wi-Fi) devices. 

 

1.2 Power and Battery Information 

 

Primary  Voltage  Input:  100-240VAC  50/60 
Hz  0.2A; and Output 12VDC: 500mA. 

 

Rechargeable battery (Ni-MH, 7.2V, 700mAh) is 
located  inside  the  console,  which  serves  as  a 
backup in case of a power failure.  

 

When the battery is fully charged, it serves as a 
backup  power  source  for  a  period  of  at  least 
24hrs.  It can take up to 48hrs to fully charge the 
battery. 24hr  test  performed  in  the  toggle  mode 
(1 way voice).

 

 

Battery switch (located at the bottom of console) 
is  set  to 

ON

  by  default.  If  switched  to 

OFF

,  the 

battery  will  be  disconnected  and  will  not  be 
charged,  nor  will  it  serve  as  a  backup  power 
source when AC power is missing.

 

 

 

 

Summary of Contents for IC 3000

Page 1: ...Table of Contents IC 3000 MANUAL Installation Programming Operation 10 24 2012 Ver 1 9...

Page 2: ...3 Console Battery 5 2 4 Pendant Smoke Detector Other Devices Low Battery 5 2 5 No Pendant Present 6 2 6 Automatic Check in Report Periodic Test Call 6 2 7 Learning Remotes 1 2 6 2 8 Communication Form...

Page 3: ...he console should not be placed close to any heat source such as direct sunlight microwave oven which can reduce signal strength The console should not be located alongside other radio transmitting de...

Page 4: ...ndant supervisory 2 NURSE button Pendant Electrical Specifications Frequency 433 92 Mhz Battery CR2032 3V 230mAh Battery life Typical life expectancy of 5 yrs at an average use rate of one activation...

Page 5: ...the Power LED is ON and the Status LED is OFF NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are...

Page 6: ...thin 1 hour the console will transmit an AC Power Fault Report to the Monitoring Station Once power has been restored and stays on for at least 1 hour the console will transmit an AC Power Restore Rep...

Page 7: ...of Step 2 press the RED pendant button Zone is occupied Desired action Within 20 seconds of Step 3 Change to a different Zone Enter a different Command different Zone number Remove current device Pres...

Page 8: ...se Call Placed If CANCEL button was pressed before or after the call was established it will cancel hang up the call If RED Emergency button console or pendant was pressed at any time during the nurse...

Page 9: ...ep 2 If the access code is not entered or validated within this time frame the system will exit the programming mode Once in Local programming mode failure to enter any Commands within a 2 minute peri...

Page 10: ...t beep in the handset cell phone Next enter the telephone number example 18001234567 followed by the sign An audible beep will be heard This will indicate that the telephone number has been programmed...

Page 11: ...and 04 0 0 Contact ID 1 Pulse 4 2 If Contact ID is selected data is transmitted to the Monitoring Station via the ADEMCO Contact ID Standard If Pulse 4 2 is selected data is transmitted to the Monitor...

Page 12: ...ed Command 38 Follow On Call Back Function Command 38 is used to determine mode of communication after the alarm event has been received by the Monitoring Station When this function is programmed as 0...

Page 13: ...that the unit is in remote programming mode If the system responds with a Nack low tone this means that the system did not accept the access code Re enter the code Command 42 Guard Time Delay The IC...

Page 14: ...t 10 60 10 60 minutes Factory default is set as 60 60 minutes During the two way voice communication period the IC 3000 will emit two beeps via the telephone handset to alert the Monitoring Station th...

Page 15: ...See Section 2 1 for answering hanging up instructions Learning Removing Pendants and Devices The IC3000 can support a maximum of 10 zones composed of pendants devices Cmd Functions 60 Remove all zone...

Page 16: ...n be learned in are PIR Sensor PIR Door Window Sensor DW Smoke Detector SD Carbon Monoxide CO Fixed Panic Button PB Pendant Transmitter WTR Tele Medical Device TMD When programming any command if a si...

Page 17: ...ore u When the IC 3000 Low Battery status is restored to the required backup power level the Status LED will stop flashing Amber and the system will return to the Idle Mode l E333 No WTR Learned In u...

Page 18: ...sent when AC power fails for more than 10 seconds the Green Power LED flashes 94 AC Failure Restore Signal is sent when the AC power is restored to the IC 3000 73 Panel Low Battery When the IC 3000 is...

Page 19: ...e 1 Enable Beep Disabled 33 Beep Help arrived signalling 0 Off 1 On Beep Off 34 Beep Nurse Button Directed to Emergency Line Beep Disabled 38 Beep Follow On Call Back Function 0 Follow On 1 Call Back...

Page 20: ...evice 4 Beep 65 Beep Learn in Pendant Device 5 Beep 66 Beep Learn in Pendant Device 6 Beep 67 Beep Learn in Pendant Device 7 Beep 68 Beep Learn in Pendant Device 8 Beep 69 Beep Learn in Pendant Device...

Reviews: