LEDs show pulsing animation in white: the internal control electronics are conducting a 

start process with self-diagnostics functionality

• 

One or more LEDs light up or flash yellow: WARNING, see 

[section 6.1]

• 

One or more LEDs light up or flash red: FAULT, see 

[section 6.2]

• 

In the CHARGE 

[section 5.2.2]

 and DISCHARGE 

[section 5.2.3]

 operating states, the 

current charge status of the instagrid ONE max is indicated through the number of LEDs 

continuously lit up green

• 

Each LED segment corresponds to a charge of 12.5%  

 

5.2 Operating states

5.2.1 OFF

The instagrid ONE max is in the OFF state when the 

rotary switch is in the 

 position, the charging inlet is 

not connected to the mains and all LEDs 

[5]

 have gone 

out. In this state, the main storage unit is connected 

neither to the charging inlet 

[8]

 nor the outle

[4 | 9]

 and 

instead is in a standby mode, which is exited when the 

charging inlet is connected to the mains. Use this operating state if you do not want to 

supply a connected load with power for a short period of time.

5.2.2 CHARGE

The instagrid ONE max is in the 

CHARGE state when the rotary switch 

is in the 

 position and the charging 

inlet is connected to the mains. 

 

The LEDs display a green-coloured 

progressive animation. In this state, the 

main storage unit is connected to the charging inle

[8]

, and the outle

[4 | 9]

 is voltage-

free. Use this operating state when you want to recharge the instagrid ONE max after 

use, or to charge the instagrid ONE max prior to long-term storage; see 

[section 9.1]

.

Note: the plug of the charging cable must first be connected to the instagrid ONE max 

and then turned clockwise until it noticeably latches in.

Note: once all LEDs are continuously lit up green, the actual charging process ends, 

but the cells undergo a balancing program for another approx. 60 minutes. It is 

recommended that you disconnect the instagrid ONE max from the mains only once this 

time has lapsed.

Note: it is possible to connect the instagrid ONE max to the mains via the charging inlet 

provided the rotary switch [3] is still in the 

 position and to start the charging process 

at a time of your choice by placing the rotary switch in the 

 position.

Summary of Contents for ONE max

Page 1: ...USER MANUAL V2 0 ...

Page 2: ...this are all devices that feed power into the supply grid e g plug in solar panels Also exempt are devices that rely on a protective conductor connection to perform safety functions Due to the special design of the instagrid ONE max both the operation of sensitive loads e g AV equipment and the use of devices with strong feedback effects on the AC supply e g caused by high starting currents or rea...

Page 3: ...way from external heat sources e g long solar radiation radiant heaters fire Contact with ambient air must not be restricted e g through operation in a sealed container The instagrid ONE max must neither be used nor stored in an area at risk of explosion The instagrid ONE max must not be moved using cranes lifting aids or other lifting equipment In order to prevent injury from the instagrid ONE ma...

Page 4: ...grid ONE max if the power cable exhibits a defect or the insulation is damaged Protect the power cable so that it can neither become crushed kinked nor damaged in any other way In particular pay attention to the power plug and the charging port 8 on the instagrid ONE max A replacement cable can be sourced directly from instagrid see section 10 The instagrid ONE max can only be disconnected from th...

Page 5: ...let 10 4 INITIAL COMMISSIONING 10 5 OPERATING STATES AND OPERATION 11 5 1 Concept of operation 11 5 2 Operating states 12 5 2 1 OFF 12 5 2 2 CHARGE 12 5 2 3 DISCHARGE 13 5 2 4 TRANSPORT 13 5 3 Features 14 5 3 1 Starter battery 14 6 WARNINGS AND FAULTS 14 6 1 Warning 14 6 1 1 External problems 14 6 1 2 Temperature problems 15 6 2 Faults 15 7 SERVICE AND MAINTENANCE 15 7 1 Replacing the charging inl...

Page 6: ...uring defects and undertakes to repair or replace any defective parts free of charge The period of limitation for claims for defects is 24 months following delivery 1 SCOPE OF SUPPLY Thank you for purchasing the instagrid ONE max Check the completeness of the delivery following receipt The following parts must be included instagrid ONE max Charging cable User manual ...

Page 7: ... lithium ion batteries are sealed so as to be gas tight and harmless as long as the manufacturer s instructions are followed during use and handling The user is liable for any improper use see section B 1 The instagrid ONE max offers the option of communication with a smartphone tablet or a PC via an in built Bluetooth interface You can find more information on this at https instagrid co manuals 2...

Page 8: ...n 16 A similar to B16 circuit breaker Permitted operating temperature 20 C to 60 C Operating state Charge Input voltage 120 240 V AC 50 60 Hz Rated power 500 1 000 W 4 A Power consumption when charging process fully complete 0 5 W Charging time 3 h to 100 Permitted operating temperature 0 C to 45 C General information Capacity 2 074 Wh Weight 20 kg Dimensions 420 210 420 mm Protection rating IP54 ...

Page 9: ...es at 20 A for 27 5 minutes Thermally induced shutdown the internal temperature of the instagrid ONE max is monitored continuously during operation Exceeding the fixed limit values leads to a shutdown of the instagrid ONE max see section 6 1 2 The time after which the shutdown is triggered varies depending on ambient temperature and load current At 25 C and 16 A a complete discharge of the instagr...

Page 10: ...n the overall length of the cable network increases its clarity is reduced The probability of discovering a cable damaged in operation which could result in an earthing at the outlet of the instagrid ONE max reduces correspondingly Regular electrical checks of the loads used If an electrical device is used mainly in an IT isolé terre network the probability of discovering insulation faults is redu...

Page 11: ... ONE max is completely discharged Use of the switch is described in detail in section 5 2 The instagrid ONE max tells you the actual operating state through eight LEDs 7 The LEDs are also used to indicate warning and fault messages see section 6 The following characteris tics must be noted LEDs off depending on the position of the rotary switch 3 the following possibilities arise Rotary switch Cha...

Page 12: ... supply a connected load with power for a short period of time 5 2 2 CHARGE The instagrid ONE max is in the CHARGE state when the rotary switch is in the position and the charging inlet is connected to the mains The LEDs display a green coloured progressive animation In this state the main storage unit is connected to the charging inlet 8 and the outlet 4 9 is voltage free Use this operating state...

Page 13: ...ly see section 5 2 2 The main storage unit is connected to the outlet of the instagrid ONE max Even with the charging cable connected the inlet and outlet are galvanically isolated see section 3 1 Use this operating state to supply a connected load with power To do so proceed as follows Make sure that the load is switched off and is not connected to the instagrid ONE max Set the instagrid ONE max ...

Page 14: ...e fully charged after approx 12 hours The instagrid ONE max is in TRANSPORT mode and the charging inlet is connected to the mains You can expect an empty starter battery to be fully charged after approx 5 hours 6 WARNINGS AND FAULTS Due to external or internal influences conditions may arise when starting or operating the instagrid ONE max that render the further use of the instagrid ONE max impos...

Page 15: ...s maintenance and servicing free With the exception of the input fuse 11 and the frame 7 the instagrid ONE max does not contain any components or assemblies that the user needs to replace or service ATTENTION If the instagrid ONE max has damage unrelated to the frame 7 a repair must be performed by authorised specialist personnel Do not open the instagrid ONE max Under no circumstances should you ...

Page 16: ...tructions of which you can find the latest version on our website https instagrid co manuals The integrated Li Ion batteries are subject to the requirements of hazardous goods legislation Relevant national and international regulations must be complied with Before transport activate TRANSPORT mode section 5 2 4 by moving the rotary switch 3 to the position and remove connected cables and or loads ...

Page 17: ...lectronic equipment and batteries as well as those directives transposition into national law At the end of the service life the used instagrid ONE max should be handed over to authorised collection points ideally discharged Heed the regulations governing environmentally friendly disposal that apply in your area The integrated battery modules must only be removed from the instagrid ONE max by a qu...

Page 18: ...instagrid co ...

Reviews: