8.
DIAGNOSIS
To know the status of the inputs / outputs of the PLC.
On this page all operating cycles are possible by pressing the pedal and the green buttons.
Shutdown possible by button touch :
No action possible. This screen is used for troubleshooting and evaluating sensor and actuator states. The
support service can ask the operator to display it during a telephone intervention for example.
1) Inputs
2) Outputs
3) Temperature in ° Celsius or ° Fahrenheit
4) Analogue value of the static relay (resistance control) (0 to 1000 pts)
5) Active SFC Step: number of the active step during the cycle (0 to 10)
6) Totalizer counter (no reset)
7) Active mode: FULL AUTO, SEMI AUTO, 1 POST
8) Alarm in progress: access summary page alarms
9) PID control type (based on PID values)
10) Change plate and stop cycle button
11) Analogue value of pressure relay
(Output command 0 to 4095pts – Input Pressure info 1482 to 6855pts)
11) Back to previous page
2)
10)
3)
4)
1)
9)
6)
12)
5)
8)
7)
11)