background image

9

Scalding Hazard: 

Do not allow

water to boil. May result in 
severe burns.

Tank temperature is factory preset
to 200°F, which mixes with cool tap
water to produce an output water
temperature of approx. 110°F.

To reset the tank thermostat 
to 200°, turn the indicator one 
notch to the right of vertical.

After adjusting, lift faucet handle for
20 seconds for water to re-heat to the new setting.

Q

 

To adjust water temperature, turn thermostat
dial on the front of the tank clockwise to
increase temperature or turn counter clockwise
to decrease temperature. Repeat if necessary.
All changes should be minimal.

Q

Regularly inspect the unit for any signs of
leakage. If there are signs of water damage,
immediately remove the unit from service.

Q

 

To avoid water damage from leakage,
replace all cut, loose or split tubing

.

Q

 

A drain pan, plumbed to an appropriate 
drain or outfitted with a leak detector, 
should be used in those applications where
any leakage could cause property damage.

PROPERTY DAMAGE

CARE AND USE

Electric Shock Hazard: 

To prevent electrical shock, disconnect power before 

servicing unit. Use only a properly grounded and polarized electric outlet.

approx. 200°

ADJUSTING THE THERMOSTAT

Q

 

Only use mild cleaners to clean the faucet
and plastic components.

Q

 

Cleaners with acids, abrasives, alkaline or
organic solvents will result in deterioration
of the plastic components and void the
warranty. 

CLEANING THE FAUCET AND TANK

Anytime the hot water faucet is not used for extended
periods of time, unplug and drain unit. If it is below
freezing you will need to unplug the unit and drain it.

Q

 

Disconnect power from unit.

Q

 

Turn faucet lever to warm and allow
water to flow until it is cool.

Q

 

Shut the faucet off at the valve.

Q

 

Remove drain screw located on bottom
center of water tank and drain the water
into empty pail.

Q

 

Empty the tank and then reinstall drain
screw onto the bottom of tank, turning
until snug. Do NOT over tighten.

Q

 

To place back in working order, fill tank
with water and re-connect the plug.

SEASONAL STORAGE/DRAINAGE

8

Property Damage: 

To avoid water damage, replace any loose or split tubing.

Periodically inspect the unit for any signs of leakage and immediately remove from
service any unit suspected of leaking.

Personal Injury: 

This tank is a non-pressurized tank. DO NOT modify this system.

DO NOT close vent tube or connect other type faucet or valves to the tank. Use only the
InSinkErator faucet supplied. Use only parts provided. Contact an authorized
InSinkErator Service agent for repairs or replacement components.

Electric Shock Hazard: 

Using an ungrounded or improperly connected 

appliance can result in serious injury or death from electrical shock.

1-year warranty

Covers all replacement parts and labor to correct defects in material or workmanship in

the faucet system, excluding the replaceable filter cartridge, for the full warranty period from
the date of installation in your home. If warranty service is required during the warranty period,
contact an authorized InSinkErator service agent to replace or repair the unit in your home at
no cost to you. If your faucet is replaced rather than repaired, the warranty on the new unit
shall be for the duration of the remaining portion of the original dispenser’s warranty. 
Note: Warranty is determined by unit serial number and/or date of installation. Purchase or

installation receipt may be required to verify warranty status. When service is required, and for

the location of your nearest factory authorized service center, call toll free 1-800-558-5700.

The foregoing warranty does not apply to damage or inoperation resulting from accident,

alteration, misuse, abuse, improper installation, installation not in accordance with these
instructions or local electrical and/or plumbing codes. We do not assume any responsibility for
consequential damage. Install using genuine InSinkErator

®

manufactured components only. Use

of non InSinkErator components will void your warranty.

Some states do not allow limitations on how long an implied warranty lasts, or the

exclusion or limitations of incidental or consequential damages, so the above limitations or
exclusion may not apply to you. This warranty gives you specific legal rights, and you may
also have other rights which vary from state to state.

This appliance must be grounded.

This hot water faucet is equipped with a cord that has a

grounding conductor and a grounding pin. The plug must be connected to an appropriate outlet that
is properly installed and grounded in accordance with all local codes and ordinances.
Do not modify the plug provided with the appliance – if it will not fit the outlet, have a proper outlet
installed by a qualified electrician. Check with a qualified electrician or serviceman if you are in
doubt as to whether the instant hot water dispenser is properly grounded.

WARRANTY INFORMATION

Fire Hazard: 

To minimize possibility of fire, DO NOT store flammable items such as

rags, paper or aerosol cans near the tank. DO NOT store or use gasoline or other 
flammable vapors and liquids in the vicinity of this or any other appliance.

A hot water faucet, like any water heater, has a limited life and will eventually fail. To avoid

possible property damage, this hot water faucet should be regularly examined for leakage

and replaced when necessary. A drain pan, plumbed to an appropriate drain or outfitted

with a leak detector, should be used in those applications where any leakage could cause

property damage.

Summary of Contents for Ultra System

Page 1: ...do Uso Installation Sion Utilisation Owner s Manual The Emerson logo is a trademark and a service mark of Emerson Electric Co InSinkErator is a division of Emerson Electric Co 44062 0407 www insinkerator com Printed in USA 2007 InSinkErator ...

Page 2: ...required under the sink for the faucet s electrical power Q The wall outlet powering the tank must have electrical power supplied to it continuously Q This outlet must be fused and should not be controlled by the same wall switch that operates a food waste disposer unless you have a SinkTop Switch from InSinkErator Q If you suspect elevated levels of chlorine in your water it is recommended to use...

Page 3: ...used It should not be controlled by the same wall switch that operates a food waste disposer PREPARATION START HERE PROPER INSTALLATION SHOULD TAKE ABOUT 2 4 HOURS Q Identify locations for the faucet and tank Q Check to make sure there is proper clearance for faucet handle to be fully opened Q Check to make sure counter is not too thick Q Make sure there is a grounded electrical outlet under the s...

Page 4: ...e on the spot selected for installation use a pencil to mark locations for 2 hanging screws Property Damage Tank must be located within 16 of faucet and within 30 or less of a standard grounded outlet DO NOT extend plumbing or electrical lines 3 MOUNTING THE TANK Tank must be mounted level to ensure proper operation Mount tank vertically in an area that allows clearance on the underside of the tan...

Page 5: ...in serious injury or death from electrical shock 1 year warranty Covers all replacement parts and labor to correct defects in material or workmanship in the faucet system excluding the replaceable filter cartridge for the full warranty period from the date of installation in your home If warranty service is required during the warranty period contact an authorized InSinkErator service agent to rep...

Page 6: ...nt d 0 setting few ully e mounted ened 00 ...

Reviews: