background image

Service/Maintenance Instructions 

Adjusting Temperature 

The thermostat is pre-set at the factory. If a thermostat adjustment 
is required, unplug the power cord and remove the screw and 
access cover. Insert a small screwdriver in the slot of the thermo-
stat adjusting screw. Turn clockwise 1/2 notch to increase the 
water temperature and counterclockwise 1/2 notch to decrease the 
water temperature. 

replace the access cover and reconnect electric power. Draw 3 or 

cups of water and allow unit to heat. Repeat  the process until 
desired temperature is reached.

 Do not allow water to boil.

 

What to do if something 
goes wrong 

1.   If the dispenser's flow of water slows or stops, make sure the

 

water supply valve is not plugged or turned off. To unplug the 
valve, turn it all the way off and then open it all the way. This 
may dislodge any foreign material. If this does not work, then 
unplug the power cord and contact your service center. 

2.   Be sure dispenser is plugged firmly into a properly grounded 

outlet. 

  Check that fuses and circuit breakers are working. Reread    

instruction booklet to assure that you are using correct 
operating procedure. Many unnecessary service calls result in 
the service agent doing what the owner can do for himself. 

3.  Contact your local authorized service center. For the location  

of your nearest factory authorized service center call 1-800-
558-5700 USA (1-800-367-9811 Canada). 

4.  Write to us if a satisfactory solution Is not reached in the steps 

above. Our address is shown below. 

What if water is dripping from 
the spout? 

If water drips from the spout, draw 2 or 3 cupfuls while unit is 
heating. This will drain any water out of the unit's expansion 
chamber. If water still drips prior to the automatic thermostat 
shutting off (you can hear it), turn thermostat to a slightly lower 
temperature setting. See thermostat adjustment procedure at 
left. 
If the water pressure occasionally drops below 20 pounds per 
square inch (138kPa), the expansion chamber of the tank may 
not be draining properly. In such a case, water may drip from 
the spout until the incoming water is hot enough to turn off the 
thermostat. As soon as adequate water pressure is restored, 
the next drawing of water will clear the expansion chamber. 
Occasional drops in water pressure will not harm the operation 
of your unit. 

NOTE: Use only mild cleaners to clean the dispenser spout and 
plastic components. Use of cleaning agents containing acids, 

alkalines and organic solvents will result in deterioration of 
plastic components. 

Full One-Year Warranty 

Beginning from the date of installation through one year of use 
in your home, we will repair or replace at no charge defects in 
material or workmanship which appear in the dispenser. If your 
dispenser is replaced rather than repaired, the warranty on the 
new unit shall be for the duration of the remaining portion of the 
original dispenser's warranty. Please call the nearest Factory 

Authorized

 Service Center when service is needed

.

 

For the location of your nearest factory authorized service cen-
ter, call this toll free number:  1-800-558-5700 USA (1-800-367-
9811 Canada). 
This full one-year warranty applies only if the unit is installed in 
accordance with these installation instructions, is used on 
circuits and currents specified, and has had normal use and 
service. 
The foregoing warranty does not apply to damage or inopera-
tion resulting from accident, alteration, misuse, abuse, improper 
installation, installation not in accordance with these instruc-
tions or local electrical and/or plumbing codes or shows evi-
dence of having been started up "dry". We do not assume any 
responsibility for consequential damage. 

IN-SINK-ERATOR DIVISION 
EMERSON ELECTRIC CO.         
4700 21st STREET                   
RACINE, WIS., 53406-5093 

Part Number 42752

 

 

 

Summary of Contents for Steamin' Hot H-770

Page 1: ...understands the Safety Instructions contained in this manual This appliance produces extremely hot water Do not allow children to operate this appliance How your hot water dispenser works Water is el...

Page 2: ...re to refill tank with water before reconnecting the electrical plug Review step 9 Connecting the dispenser to your regular water supply requires no special plumbing All details are covered in the ins...

Page 3: ...le working the lubes down slowly with your other hand See Caution step 8 NOW WE INSTALL THE DISPENSER HEAD APlace the dispenser head with 10 24 mount BWorking from below sink place semi circular CNow...

Page 4: ...NOW LETS CONNECT THE WATER TO DISPENSER HEAD Before you start open the valve and let a small amount of water run through it into a pan This will flush the line of any sediment When connecting to a com...

Page 5: ...t space for drain screw any material other than wood access C Hang the tank on the bracket There is room to adjust the bracket if necessary CAUTION Product damage Do not connect electric power until t...

Page 6: ...dure Your dispenser However when the 190 F 88 C temperature is should now be operating properly being reached you can expect a gurgling or hissing Note The dispenser perks like a coffee percolator sou...

Page 7: ...94HF 1 flammabllity specification Valve Instant self closing Shipping weight 9 Ibs 4 kg Model H 778 Commercial Model only This model comes with a 4 chrome extension sleeve for the tap To attach slide...

Page 8: ...tat to a slightly lower temperature setting See thermostat adjustment procedure at left If the water pressure occasionally drops below 20 pounds per square inch 138kPa the expansion chamber of the tan...