54
®
PART 7 ELECTRICAL SCHEMATICS & PARTS
TRAC 878 Technical Manual 2018
www.insingermachine.com 800-344-4802
SK-4470 :
Control Panel Layout (Security)
FUSE REQUIREMENTS
Voltage
208 V 230 V 380 V 460 V
Motors
30 A
30 A
20 A
15 A
Heaters
30 A
25 A
15 A
15 A
FUSE PART NO.
15 A
FNQ-R-15
DE9-183
20 A
FNQ-R-20
DE9-184
25 A
FNQ-R-25
DE9-220
30 A
FNQ-R-30
DE9-227
PARTS NOT SHOWN
PART NO.
DESCRIPTION
QTY
Electric Immersion Heater (3kW)
2
DE13-SC73 440 - 480 V, 3 PH
DE13-SC53 380 V, 3 PH
DE13-SC43 220 - 240 V, 3 PH
DE13-SC23 208 V, 3 PH
Electric Immersion Heater (5kW)
2
DE13-SD73 440 - 480 V, 3 PH
DE13-SD53 380 V, 3 PH
DE13-SD43 220 - 240 V, 3 PH
DE13-SD23 208 V, 3 PH
DE5-70
Stop Pushbutton Station
1
DE9-231
Optional Audible Conveyor Jam Alarm
1
DE9-252
Temperature Sensor
2
DE6-26
Transformer, 250 VA (DC Drive Option)
1
DE3-3
Terminal Block (Heaters)
2
REV E - 03/09/18