9
OUTPOST
www.insingermachine.com
800-344-4802
MAINTENANCE
MAINTENANCE REQUIREMENTS
This section is intended for qualified service and/or maintenance
technicians.
The following maintenance should be conducted if any
operational problems develope:
1.
Unlock the units hood and tilt foward.
2.
Inspect the condition of all hoses / tubes and fittings. Look for
sanitizing liquid leaks.
3.
Disconnect the discharge hose at the tubing leading to the
nozzle and remove the dress panel with its attached hood. There
are 2 screws along each side at the back and 2 screws below
the foot pedal for a total of 6 screws.
4.
Inspect the pump for cracks and any loose hoses .
5.
Press the foot pedal downward and release. The internal spring
of the pump sould return the foot pedal to the upward position.
6.
Verify that the nozzle sprays sanitizing agent freely. Remove
any hardened buildup that may prevent proper flow.
7.
Reinstall the Dress Panel / Hood combination. Reconnect the
discharge hose to the metal tubing leading to the nozzle.
8.
Tilt the Hood Back and lock the unit.
CLEANING INSTRUCTIONS
DAILY CLEANING
The following cleaning procedures should be done daily, at the end of
the shift:
1.
Wipe up any sanitizing liquid that may have accumulated in the
catch tray.
2.
Ensure any sanitizing liquid that may have dropped on the floor
from the hands of people during normal use is wiped up.