MAINTENANCE

 

MAINTENANCE REQUIREMENTS

This section is intended for qualified service and/or maintenance

technicians.

The following maintenance should be conducted if any 

operational problems develope:

1.

Unlock the units hood and tilt foward.

2.

Inspect the condition of all hoses / tubes and fittings. Look for 

sanitizing liquid leaks.

3.

Disconnect the discharge hose at the tubing leading to the 

nozzle and remove the dress panel with its attached hood. There

are 2 screws along each side at the back and 2 screws below 

the foot pedal for a total of 6 screws.

4.

Inspect the pump for cracks and any loose hoses .

5.

Press the foot pedal downward and release. The internal spring 

of the pump sould return the foot pedal to the upward position.

6.

Verify that the nozzle sprays sanitizing agent freely. Remove 

any hardened buildup that may prevent proper flow.

7.

Reinstall the Dress Panel / Hood combination. Reconnect the 

discharge hose to the metal tubing leading to the nozzle.

8.

Tilt the Hood Back and lock the unit.  

 

 

CLEANING INSTRUCTIONS

DAILY CLEANING

The following cleaning procedures should be done daily, at the end of 

the shift:

1.

Wipe up any sanitizing liquid that may have accumulated in the 

catch tray.

2.

Ensure any sanitizing liquid that may have dropped on the floor 

from the hands of people  during normal use is wiped up.

 

 

Summary of Contents for OUTPOST

Page 1: ...ion and Maintenance Instructions OUTPOST FOOT PEDAL OPERATED FLOOR WALL MOUNTED Insinger Machine Company 6245 State Road Philadelphia PA 19135 2996 800 344 4802 Fax 215 624 6966 www insingermachine com HAND SANITIZING UNIT P N 9700 02327 ...

Page 2: ...eration If the need for service should arise please contact your local Authorized Insinger Service Company To find your local authorized Service Company please visit our web site www insingermachine com or call Insinger at 800 344 4802 Please read all installation and operation instructions carefully before attempting to install or operate your new Insinger product For answers to question concerni...

Page 3: ...3 OUTPOST www insingermachine com 800 344 4802 SPECIFICATION SHEET 39 50 31 75 36 50 12 00 10 50 13 50 9 38 REMOVED FOR UNITS PLACED AGAINST A WALL 4 75 1 75 ...

Page 4: ... If the unit is greater than 3 inches away from the wall it is recommended that the rear foot be installed FOR FREE STANDING UNITS 1 Unlock the units hood and tilt foward 2 Locate the Rear Foot that is mounted to the upper back of the unit Remove the foot and retain the 4 screws and the 4 lockwashers 3 Install the Rear Foot to the back of the unit as illustrated The slots will allow for a certain ...

Page 5: ...screws below the foot pedal for a total of 6 screws 3 There are two holes in the base that are 6 inches apart that can be utilized to bolt the base down Any bolts and or anchoring points are entirely the responsibility of the customer 4 After securing base Reinstall the Dress Panel with the attached Hood 5 Reconnect the Hose to the metal tubing leading to the nozzle 6 Follow bottle changing proced...

Page 6: ... a fine mist for alcohol based sanitizers and in a stream for sanitizing gels 4 After the spray stops release the foot pedal 5 If additional sanitizing agent is desired repeat the process 6 Rub hands together throughly for 30 seconds to ensure that all areas of your hands are covered Dispensing Nozzle Catch Tray Foot Pedal NOTE If sanitizing agent is not present after repeated attempts ensure that...

Page 7: ...ent it from fallng down into the base of the unit Elevating the hose will prevent the loss of any liquid within the hose and will make priming of the new bottle easier 4 Remove the old bottle from its holding tray 5 Obtain a new bottle of sanitizing agent and place it upon the holding tray 6 Remove the new bottles cap and any protective seal that may be present 7 Insert the Suction Hose into the n...

Page 8: ...TTLE REPLACEMENT Continued 9 Close the Dispenser Hood while ensuring the discharge hose does not become kinked in the process 10 Lock the hood by turning the key in the clockwise direction 11 Operate the dispenser to ensure that the sanitizing agent flows freely ...

Page 9: ... a total of 6 screws 4 Inspect the pump for cracks and any loose hoses 5 Press the foot pedal downward and release The internal spring of the pump sould return the foot pedal to the upward position 6 Verify that the nozzle sprays sanitizing agent freely Remove any hardened buildup that may prevent proper flow 7 Reinstall the Dress Panel Hood combination Reconnect the discharge hose to the metal tu...

Page 10: ...7000 02236 1 2 W Hood Weldment 7100 02235 1 3 F Foot Rear Support 7000 02247 2 4 Lock Keyed Cam 6330 02261 1 5 Decal Insinger 9600 02307 1 6 Decal Hand Sanitizer 9600 02308 1 7 Foot 1 Pad NOT SHOWN 6310 02331 4 8 10 OUTPOST www insingermachine com 800 344 4802 REV ASSEMBLY DRAWINGS 5 3 2 4 1 6 7 ...

Page 11: ...11 OUTPOST www insingermachine com 800 344 4802 REV ASSEMBLY DRAWINGS 7 9 11 10 8 12 4 16 15 14 13 4 6 1 3 2 5 5 CUSTOMER SUPPLIED 1 GALLON BOTTLE 17 ...

Page 12: ...Plate Nozzle Positioning 7000 02283 1 7 Tube Nozzle Supply 7500 02287 1 8 Bracket Nozzle Positioning 7100 02255 1 9 Nozzle Duckbill 4575 02312 1 10 Washer 5 16 SS 5330 01486 1 11 Fitting Liquid Tight Snap In 5915 02319 1 12 Hose Suction 7500 02243 1 13 Cap 1 1 2 OD Jug Opening 3200 02325 1 14 Fitting Straight Connector 4820 02321 1 15 Hose Bottle Suction 7500 02330 1 16 Weight Suction Tube 7100 02...

Reviews: