7
OUTPOST
www.insingermachine.com
800-344-4802
MAINTENANCE
1.
Obtain the key for the hood lock and turn the lock
counterclockwise.
2.
Tilt the Hood foward to expose the sanitizer bottle. Inspect the
bottle to ensure the sanitizer level. If sanitizing level is adequate,
check for other conditions that would prevent the dispensing of
sanitzing agent. (Refer to the troubleshooting section)
3.
If the level is inadequate, remove the bottle top by rotating
counterclockwise and then pull the cap and its attached suction
hose from the old bottle. Secure the bottle top with connected
hose to prevent it from fallng down into the base of the unit.
(
Elevating the hose will prevent the loss of any liquid within
the hose and will make priming of the new bottle easier
).
4.
Remove the old bottle from its holding tray.
5.
Obtain a new bottle of sanitizing agent and place it upon the
holding tray.
6.
Remove the new bottles cap and any protective seal that may
be present.
7.
Insert the Suction Hose into the new bottle and secure the bottle
cap by turning clockwise until snug.
8.
Slowly and repeatedly press the foot pedal downward and
release unitil sanitizing agent is visible within the hose and
approaches its end. This will take several pushes to expell all air
from the lines.
WARNING:
WEAR PROTECTIVE FACE SHIELD
OR GOGGLES TO PREVENT CHEMICAL
AGENTS CONTACTING YOUR EYES
BOTTLE REPLACEMENT