www.insingermachine.com 800-344-4802
Check-Out of the Installation
Perform the Start-up Procedure.
WARNING:
At startup, and after any draining of the
electric booster, turn off the 440 volt
power to the booster during the initial
operation of the final hot fresh rinse.
This will allow the booster reservoir to
fill and trapped air to be purged without
overheating of booster heating elements.
!
Verify that pump and motor rotations are correct. An
arrow on the pump casting indicates the correct direc-
tion. Observe direction of loader roller rotation and
unloader chain motion.
Inspect all plumbing joints for leakage and verify that
water is running freely through the drains.
With the machine at operating temperature, and with the
shipboard exhaust system operating, adjust the damper
blade position in each vent duct connection. Starting
with fully open blades, close each blade until a small
amount of vapor escapes from the entrance and exit
ends of the machine. Then open each blade a small
amount and lock the handle position with the wing nut.
34