6
CX20 SERIES
www.insingermachine.com 800-344-4802
PART 1 TECHNICAL INFORMATION
ELECTRICALLY HEATED / DUAL POINT CONNECTION
ELECTRICALLY HEATED / SINGLE POINT CONNECTION
VOLTS PHASE FREQ
WASH
MOTOR
WASH
HEATER
RINSE
HEATER
CONTROL
TOTAL
LOAD
MCA
MOP
208
1
60
9.2 A
43.3 A
43.3 A
0.27 A
96.1 A
125 A
125 A
240
1
60
9.1 A
37.5 A
37.5 A
0.24 A
84.3 A
110 A
110 A
208
3
60
4.7 A
25.0 A
25.0 A
0.27 A
54.0 A
70 A
70 A
240
3
60
4.2 A
21.7 A
21.7 A
0.24 A
47.8 A
60 A
60 A
480
3
60
2.1 A
10.8 A
10.8 A
0.12 A
23.8 A
30 A
30 A
CONNECTION #1
VOLTS PH FREQ
WASH
MOTOR
WASH
HEATER
CONTROL
TOTAL
LOAD
MCA MOP
208
1
60
9.2 A
43.3 A
0.27 A
52.8 A 70 A 70 A
240
1
60
9.1 A
37.5 A
0.24 A
46.8 A 60 A 60 A
208
3
60
4.7 A
25.0 A
0.27 A
30.0 A 40 A 40 A
240
3
60
4.2 A
21.7 A
0.24 A
26.1 A 35 A 35 A
480
3
60
2.1 A
10.8 A
0.12 A
13.0 A 20 A 20 A
CONNECTION #2
VOLTS PH FREQ
RINSE
HEATER
TOTAL
LOAD
MCA MOP
208
1
60
43.3 A
43.3 A 60 A 60 A
240
1
60
37.5 A
37.5 A 50 A 50 A
208
3
60
25.0 A
25.0 A 35 A 35 A
240
3
60
21.7 A
21.7 A 30 A 30 A
480
3
60
10.8 A
10.8 A 15 A 15 A
STEAM HEATED / SINGLE POINT CONNECTION
VOLTS PH FREQ
WASH
PUMP
CONTROL
TOTAL
LOAD
MCA
MOP
208
1
60
9.2 A
0.31 A
9.5 A
15 A
15 A
240
1
60
9.1 A
0.26 A
9.4 A
15 A
15 A
208
3
60
4.7 A
0.31 A
5.0 A
15 A
15 A
240
3
60
4.2 A
0.26 A
4.5 A
15 A
15 A
480
3
60
2.1 A
0.13 A
2.2 A
15 A
15 A
NOTE: ALWAYS REFER TO THE MACHINE DATA PLATE FOR SPECIFIC ELECTRICAL AND WATER REQUIREMENTS. THE
MATERIAL PROVIDED ON THIS PAGE IS FOR REFERENCE ONLY AND IS SUBJECT TO CHANGE WITHOUT NOTICE.
ELECTRICALLY HEATED (NO BOOSTER) - SINGLE POINT CONNECTION
VOLTS PH FREQ
WASH
MOTOR
WASH
HEATER
CONTROL
TOTAL
LOAD
MCA
MOP
208
1
60
9.2 A
43.3 A
0.27 A
52.8 A
70 A
70 A
240
1
60
9.1 A
37.5 A
0.24 A
46.8 A
60 A
60 A
208
3
60
4.7 A
25.0 A
0.27 A
30.0 A
40 A
40 A
240
3
60
4.2 A
21.7 A
0.24 A
26.1 A
35 A
35 A
480
3
60
2.1 A
10.8 A
0.12 A
13.0 A
20 A
20 A
ELECTRICAL REQUIREMENTS