background image

 

www.insigniarange.com

 

Last Modified: 08/02/2018

 

 08 

Insignia Screw Pack

 

VERY IMPORTANT

 

Have you got everything? If not please contact the Insignia Support Line on 01908 226545. Remember 

NEVER

 book your tradesman until everything has arrived, been 

checked and is present. No replacement/missing parts can be obtained free of charge during or after the build. Any claims can only be within the timescale permitted (48 

hours after delivery) and always 

BEFORE

 build.

 

Note: In some cases you may have more screws than needed, this is done so you have spares!

 

Product Code

 

Description

 

Quantity

 

SP097

 

Door Handles

 

2

 

SP276 and SP276A

 

White Door Wheels

 

4 of each

 

ST20

 

20mm Screws 

 

20

 

ST35

 

35mm Screws

 

10

 

M4

 

20mm Nut and Bolt

 

20

 

ST14

 

14mm Screws

 

20

 

ST25

 

25mm Screws

 

10

 

SW9

 

Small Washers

 

20

 

DB6

 

Drill Piece

 

1

 

Summary of Contents for INS9005

Page 1: ...arts inside of your warranty contact www insigniarange co uk customerService aspx Spares Replacements Parts outside of your warranty contact 0844 800 3069 www insigniarange co uk WARRANTY REG NO _____...

Page 2: ...rical Requirements What s In The Boxes Screw Pack Contents Plumbing Requirements Schematics Starting The Installation Electric Box Connections Steam Generator Connections Sealing and Water Testing Con...

Page 3: ...ny years to come Like everything in order to obtain a first class product that will serve you well for many years the effort and correctness put into the assembly will reflect in the quality of your f...

Page 4: ...D ELECTRICAN COMPANY TO COMPLETE THE CONNECTION FROM SHOWER TO THE HOUSE SUPPLY LAWS DEMAND IN MANY CASES YOU DO THIS AND YOUR WARRANTY IS VOID IN REGARDS TO THE ELECTRICAL ITEMS IF THIS IS NOT UNDERT...

Page 5: ...ician This product comes with 13 amp plug s fitted with an RCD unit We leave it this way for you to connect this your own way due to continued additions to current regulations 1 Connect within current...

Page 6: ...Electric Drill Tool Requirements None Supplied Adhesive Requirements Bacteria Resistant Sanitary Silicone for vertical joints RubberGum Plumbers Mait for waste joints Not Supplied Supplied Not Supplie...

Page 7: ...Y RUN this means you do not silicone anything just simply construct the shower align drill and screw everything together Once you are happy with the build take the unit apart and carry out the final f...

Page 8: ...s can be obtained free of charge during or after the build Any claims can only be within the timescale permitted 48 hours after delivery and always BEFORE build Note In some cases you may have more sc...

Page 9: ...r plumber The end delivery however must fall within the scope above Important Note Do not exceed 3 4 BAR pressure under any circumstances Warranty is void if so as damage will occur If you have a comb...

Page 10: ...www insigniarange com Last Modified 08 02 2018 10...

Page 11: ...de of the waste supplied in the optional fitting kit you will notice a spigot not seen on an ordinary waste In most cases this is blanked yet should you have a steam version you need to gently drill t...

Page 12: ...using the M4 Nut and Bolt Ensure you run a bead of silicone between the 2 panels and apply Rubbergum under the bottom of both panels Step 2 Attach the large back panel to the left column using the M4...

Page 13: ...d of silicone between the 2 panels and Rubbergum along the bottom of the tray Step 3 The next step is to attach the remaining column with control panel to back mir rored panel using the M4 NUT AND BOL...

Page 14: ...www insigniarange com Last Modified 08 02 2018 14 Step 5 Attach both uprights to your top and bottom rails using the ST35 screws...

Page 15: ...anels into place by pushing them as per the arrows in the adjacent image Making sure the edge of the glass with the rubber seal fits into the grove tightly Using the ST14 Screws and the SW9 washers se...

Page 16: ...www insigniarange com Last Modified 08 02 2018 16 Step 7 Place and screw the upright curves into position using the ST20 screws and SW9 washers as indicated by the images...

Page 17: ...al position Now meet the front frame to the side panels as per the image and screw together using the ST14 screws and SW9 washers We recommend Rubbergum is placed under the front frame to add to the r...

Page 18: ...nge com Last Modified 08 02 2018 18 Step 9 Now align the roof to the glass panel and secure into position using the ST20 screws and repeat this process to fix the glass panels to the tray as indicated...

Page 19: ...lf into your shelf brackets and secure by tightening the grub screw situated on the bottom of the bracket Accessory Installation Please Note Ensure all grey backing film on the rear of the glass panel...

Page 20: ...valve to the inner black tube using PTFE tape please note this only needs to be hand tight Over tightening will snap damage the inner black tube Thermostatic Probe Insert the chrome sleeve into the h...

Page 21: ...which in turn will pull the wheels towards the track ensuring a secure a tight fit Now grease the track to ensure a smooth and long lasting operation not supplied Handles Ensuring that the inner threa...

Page 22: ...rom then turn off the water and swap over the relevant hose Alternatively remove the outer chrome knob by removing the chrome cap and loosening the grub screw please ensure not to unscrew fully as thi...

Page 23: ...Last Modified 08 02 2018 23 Connecting up the water supply Left Valve Right Valve Requires 2 x 15mm equal T Valves Not Supplied The following set up is recommended for the water supply Cold Water Sup...

Page 24: ...iarange com Last Modified 08 02 2018 24 Electric Box Connections Connect the cables below to the corresponding devices on the shower Roof Light Speaker Antenna 12V power Supply Thermostatic probe Spea...

Page 25: ...as shown below Follow the lights around in the order shown as this allows a consistent path around the entire roof and will leave you placing the last light next to the first light This is important...

Page 26: ...op of the shower cabin Because of this we have a cover that simply slots over the top secured in place around the thread of the monsoon rain shower Please note this will be screwed into position once...

Page 27: ...shower Make sure these are fitted in the correct position as they are only attached for transportation reasons only Water Inlet Connect a braided hose from the shower valve s centre feed to this open...

Page 28: ...om one side and going around to the back and then to the other side finishing at the front If you have a small leak normally caused through insufficient sealer or air bubble on assembly dry the area t...

Page 29: ...ed Other buttons will remain functional whilst in this state of lock mode Button 5 Music Press once for FM Radio and press twice for Bluetooth For tuning radio stations or connecting Bluetooth please...

Page 30: ...tep 1 To tune your radio channels firstly press the music function button which looks like a musical note Tuning your radio channels Step 1 To connect a device via Bluetooth press the music function b...

Page 31: ...contains many useful items such as is your parts warranty registered advice on cleaning servicing your shower cabin fault finding and many more items This is a MUST to read and not just HELP It saves...

Page 32: ...escription SP300 Waste hose SP301 White insulated pipe SP187 Drain Hose SP234 Vertical steam generator SP308 Magnetic door seals SP310 Rear door seals SP173 SP086 SP095 SP044 SP182 SP043 3 port 3 feed...

Page 33: ...used in any way shape or form with out written permission from Maclean International Ltd Images are NOT permitted to be saved printed or uploaded Violation of copyright laws are punishable by law All...

Reviews: