background image

                                                                                                                                                          insigniarange.com 

Last Modified: 23/01/2014 

 26 

Part Code 

Part Descripon

 

SP134 

Monsoon Shower head  

SP056 

Ozone Module (for Steam 

Showers) 

SP040 

Massage jet—2 open ends 

SP040A 

Massage jet—1 open, 1 closed  

SP236 

SP112 

SP120 

Riser bar 

Shower holder (warranty only) 

Water inlet (warranty only) 

SP078 

Shower waste 

SP097 

Chrome rectangular door han-

dles 

SP240 

Glass Shelf 

SP080 

Head rest 

SP050 

Seat rest 

SP196 

Thermo sensor holder 

SP072   

Door stoppers 

SP023 

Door Wheels 

SP006 

Steam Pod 

SP105 

Chrome Flexible Hose 

SP060 

Electrical extension cable   

SP239 

Foot Massager 

SP055 

Foot massager retaining knobs 

SP003 

Ring light 

SP038 

Speaker 

SP007 

Fan 

SP028 

Under water LED light 

Internal Items 

SP164 

MK117 Control panel 

SP190 

Blister pack 

SP152 

Standard shower head 

Sp166 

Approximately 4 meters of 

“U Style” seals 

SP057 

90 Degree Chrome Water 

Inlet (for foot massager) 

SP121 

Column lights 

SP213 

Roof lights 

SP037 

Fan & Speaker cover 

SP185 

Bath Filler 

SP059 

Air valve operaon switch

 

SP098 

Chrome air jet 

SP052 

Whirlpool pump switch 

SP058 

Skirt Light 

SP058a 

End skirt light 

Part Code 

Part Descripon

 

SP300 

Waste hose 

SP301 

White insulated pipe 

HOSE1MBB 

1M braided hose w/ 

blue band 

HOSE1MBR 

1M braided hose w/ red 

band 

SP221 

Drain Hose 

SP233 

steam generator/electric 

box 

External Items 

 

Parts List 

Part Code 

Part Descripon

 

GT8058R-11 

Top Rail 

GT8058R-12 

Boom rail

 

GT8058R-3 

Tub 

GT8058R-4 

Blank roof 

GT8058R-5 

Blank column 

GT8058R-14 

Le Upright

 

Framework 

Part Code 

Part Descripon

 

GT8058R-8 

Right Backwall (angled 

piece) 

GT8058R-7 

Le Backwall 

 

(rectangular piece) 

GT8058R-6 

Glass door   

GT8058R-9 

Front fixed glass (Angled 

piece) 

GT8058R-10 

Front fixed glass (Curved 

piece) 

Glass 

SP155 

5 port—3 feed thermo-

stac valve

 

SP309 

Rear door seal 

SP312 

Magnec door seals

 

Summary of Contents for GT 8058R

Page 1: ...s details and your postcode to hand before calling Replacements Parts inside of your warranty contact www insigniarange co uk customerService aspx Spares Replacements Parts outside of your warranty c...

Page 2: ...Requirements What s In The Boxes Screw Pack Contents Plumbing Requirements Starting The Installation Electric Box Connections Steam Generator Connections Sealing and Water Testing MK117 Control Panel...

Page 3: ...years to come Like everything in order to obtain a first class product that will serve you well for many years the effort and correctness put into the assembly will reflect in the quality of your fini...

Page 4: ...L CONNECTION TO HOUSE MAINS WHEN YOUR ITEM IS ASSEMBLED ALWAYS USE THE SERVICES OF A FULLY QUALIFIED ELECTRICAL COMPANY TO COMPLETE CONNECTION FROM SHOWER TO HOUSE SUPPLY LAWS DEMAND IN MANY CASES YOU...

Page 5: ...directives using plug and RCD provided with steam version or supply one for non steam version 2 Preferred Wire into isolated fused feed connecting directly to the house consumer service box Remove th...

Page 6: ...ed When we use the word DRY RUN this means you do not silicone anything just simply construct the shower align drill and screw everything together Once you are happy with the build take the unit apart...

Page 7: ...ld Insignia Screw Pack VERY IMPORTANT Have you got everything If not please contact the Insignia Support Line on 01908 226545 Remember NEVER book your tradesman until everything has arrived been check...

Page 8: ...Warranty is void if so as damage will occur If you have a combi supply please use a pressure reducing valve if required to lower the BAR pressure to the shower Please Remember that this product is fre...

Page 9: ...is carried out In the side of the waste supplied in the optional fitting kit you will notice a spigot not seen on an ordinary waste In most cases this is blanked yet should you have a steam version yo...

Page 10: ...e column and fix together using the ST20 screws Step 2 Now apply silicone to both sides and the bottom of the control column and place the next to the angled back glass panel and fix together using th...

Page 11: ...n the direction as shown in image 1 until this locks into place as of image 2 1 2 1 2 1 2 Step 4 Apply silicone to the angled front glass and now lock the front angled glass panel to the side glass pa...

Page 12: ...er the image using the ST35 screws Step 7 Now using the ST35 screws fix the front of the top curved rail onto the upright of the front fixed angled glass Please note in order to do this you will need...

Page 13: ...and fix this into place using the ST35 screws Please note that when drilling the holes to take the screws this is at a depth no deeper than 5mm Step 9 Take the front curved glass panel and attach the...

Page 14: ...ou drill no deeper than 5mm Step 11 Pierce through the holes using a screwdriver to show pre cut holes in the glass as indicated in the image Now using the chrome L brackets fix these to the glass pan...

Page 15: ...driver to show pre cut holes in the glass as indicated in the image Now repeat the process from step 11 to secure the roof to the glass panels Step 13 Align the shower roof to your side panels and whe...

Page 16: ...on Foot Massager Fix the provided white plastic foot massage retaining knobs to your glass back panel along with your chrome water outlet as shown in the above image To hang the foot massager itself t...

Page 17: ...obe into the hole situated below the control panel roughly 6mm into the cabin and run clear silicone around the rear side of the probe Ozone o3 Unscrew the chrome pepper pot end and drop the white box...

Page 18: ...er thread Door Wheels Fit the adjustable wheels to the top and bottom of the glass doors and ensure the wheels are facing towards the rail then hang the top wheels on to the top inner curved rail Now...

Page 19: ...ng the chrome cap and loosening the grub screw please ensure not to unscrew fully as this will drop within the chrome knob this is found on the opposite side to the chrome pillar Once you have succeed...

Page 20: ...insigniarange com Last Modi ed 23 01 2014 20 Electric Box Steam Generator Connections Fan Speaker Ozone Light Light 2 Thermosta c Probe RJ11 Phone Connec on Radio Aerial AUX Audio In Connec on...

Page 21: ...e this shower if you have been drinking alcohol Never use with more than one person unless the shower is designed for this This product is not to be used for washing bathing animals Connection For Tra...

Page 22: ...ower Make sure these are fitted in the correct position as they are only attached for transportation reasons only Water Inlet Connect a braided hose from the shower valve s centre feed to this opening...

Page 23: ...round to the back and then to the other side finishing at the front If you have a small leak normally caused through insufficient sealer or air bubble on assembly dry the area thoroughly and reseal on...

Page 24: ...utton 8 TUN Switch Between manual auto radio searching Button 9 Up Arrow Channel select up manual search up Button 10 Alarm Activate Alarm Button 11 M Set Steam Time Temperature When Radio is active t...

Page 25: ...insigniarange com Last Modi ed 23 01 2014 25 Need Help If so then simply download Insignia s free comprehensive help and troubleshooting brochure now Simply visit www insigniarange co uk help aspx...

Page 26: ...ely 4 meters of U Style seals SP057 90 Degree Chrome Water Inlet for foot massager SP121 Column lights SP213 Roof lights SP037 Fan Speaker cover SP185 Bath Filler SP059 Air valve opera on switch SP098...

Page 27: ...nal Ltd All images are subject to copyright Images may not be used in any way shape or form with out written permission from Maclean International Ltd Images are NOT permitted to be saved printed or u...

Reviews: