G SERIES PILOT’S GUIDE .
INSIGHT
INSTRUMENT CORPORATION BOX 122, FORT ERIE, ONTARIO, L2A 5M6
40
Note: All Insight fuel flow transducers are factory - normalized to 30,000 pulses / gallon.
If you have a factory installed or third party transducer you may need to adjust the K- Factor of the G3 to match.
Adjust K-Factor On G2-3-4
Hold PG knob in on power up to access “Setup Mode”
You will see the “REGISTRATION CONFIG” screen
Turn PG knob to the CCW one stop
This will be the “K-FACTOR INITIALIZATION” screen
Use SEL knob to select
1) Coarse adjustment
Push SEL and turn to set
2) Fine adjustment
Push SEL and turn to set
3) The screen will show the new K-Factor expressed as “pulses per gallon”
The next line will show how much the fuel flow rate has changed since the last time it was saved.
This can be a valuable aid when tweaking your K-Factor for accurate fuel totalizing.
For example, raising the K-Factor from 30,000 to 33,000 means the fuel flow indication will
decrease by 10% next time you restart the G2-3-4.
4) Push SEL to select -
“3) SAVE CONFIG: YES NO”.
Turn SEL to highlight “YES” in RED
Push SEL . The G3-4 will display
“SAVING FLASH”.
Setup GARMIN 400/500 For Fuel Display:
1)
To start set up mode.
Press and hold “ENT” button and apply power.
Hold “ENT” until the display lights up.
Release “ENT” button, wait until display says OK
Press “ENT” button once.
2)
Turn inner rotary knob until “Main RS-232 Config” appears.
3)
Use cursor and “ENT” button to select.
4)
Press curser button to select input for channel 1
INPUT OUTPUT
Channel 1 Shadin - fadc Avtn no alt
5)
Turn power off.