background image

NVS460 User’s Guide 

 

 

 

Rev.1.0 (Sep. 2006) 

18

18

18

18 of 

 of 

 of 

 of 51

51

51

51    

 

 

4. IP-Installer 

 

NVS  460  needs  IP  network  parameters  for  connection  to  the  network  (Internet/Intranet).  IP-

Installer  is  a  PC  program  for  the  initial  network  configuration  to  IP  video  products  such  as  Video 

server  or  A/V  Server.  IP-Installer  is  provided  in  a  CD  supplied  with  NVS  460  or  it  can  be 

downloaded from “

www.inscapedata.com

”. 

 

Detailed  information  of  Installing  and  running  IP-installer  can  be  found  in  [IP-installer 

user’s guide]   

 

4.1. Main window of IP-Installer 

 

 

Figure 4-1. IP Installer 

 

All  the  basic  network  parameters  needed  for  the  initial  connection  to  IP  video  products  can  be 

assigned  by  IP-Installer.  Once  the  basic  parameters  are  assigned  and  the  initial  connection  is 

successfully  made,  you  can  connect  to  the  administration  page  for  more  sophisticated  control  of 

the  network  parameters  and  other  operational  parameters.  Refer  to  Chapter  5  for  more  details of 

the administration page. 

Summary of Contents for NVS 460

Page 1: ...0 Sep 2006 U U U User ser ser ser s Manual s Manual s Manual s Manual 1 Channel 1 Channel 1 Channel 1 Channel Video Server Video Server Video Server Video Server Encoder Encoder Encoder Encoder NVS 46...

Page 2: ...d on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and rec...

Page 3: ...nna or transmitter A minimum separation distance of 20 cm must be maintained between the antenna and the person for this appliance to satisfy the RF exposure requirements Caution Any changes or modifi...

Page 4: ...6 4 IP Installer 18 4 1 Main window of IP Installer 18 5 Configuring NVS 460 in Administrative Mode 19 5 1 Log On 19 5 2 Basic Setup 21 5 3 Network Configuration 23 5 4 Ommited Error Bookmark not defi...

Page 5: ...ensures unprecedented performance and stability to be an ideal video server solution for system integration solutions NVS 460 are offered with standard Ethernet interface while NVS 460 is offered wit...

Page 6: ...urveillance buildings stores manufacturing facilities parking lots banks government facilities military etc Real time Internet broadcasting Remote monitoring hospitals kindergartens traffic public are...

Page 7: ...0 Video server Power adapter Input 100 250V 50 60Hz Output 12V 1 0A Standard Power AC power cable AC 250V 10A 16A CD ROM Software User s Guide Quick Reference Guide Quick installation guide Will be pr...

Page 8: ...tion 2 3 1 Front View Figure 2 1 Front view of NVS 460 2 3 2 Rear View Figure 2 2 Rear side view of NVS 460 left MIC LINE IN Connect external audio source or microphone If external audio is connected...

Page 9: ...en there is traffic Status LED Green color indicates that the camera is in normal operation mode while RED color indicates that the camera is in abnormal condition RS 232C Video out 3 Pins from the bo...

Page 10: ...in the admin page Alarm Out It is used for connecting external alarm generators such as sirens flashing light etc When activated relay output configures a closed circuit Reset Factory Default Switch T...

Page 11: ...www inscapedata com 1 Connect NVS 460 to LAN by using one of the following method 1 If you have power adaptor and PoE injector connect the video server and PC as illustrated in Figure 2 4 Both power a...

Page 12: ...Inscape Data assumes no responsibility for the damages caused by use of standard PoE device with Inscape Data s products 2 Apply power to NVS 460 3 Install IP installer and NVR 100 on your PC Detailed...

Page 13: ...deo transmitted from NVS 460 Max Upload Rate Set this value smaller than the upload speed of your network Frame Rate The number of frames to be transmitted per second Basic Setup Video Rate Bandwidth...

Page 14: ...Detector 1 Alarm Out Connecting Alarm annunciating device Siren Flashing Light 1 RS485 PT device control Remote P T Z device connection having RS485 interface 1 100Base T Network connection Connect N...

Page 15: ...steps 1 to 4 in Section 2 5 to assign IP address to NVS 460 2 Install NVS 460 and connect it to desired LAN 3 Check if you can receive video data when connecting to NVS 460 using the viewer program 4...

Page 16: ...evice 3 2 Connecting to xDSL Cable Modem 1 Follow through steps 1 to 4 in Section 2 5 to assign IP address and other network parameters to NVS 460 2 Install NVS 460 and connect it to xDSL or Cable mod...

Page 17: ...way of connecting to your video server under dynamic IP environment Please refer to the Application note regarding Management Server in the CD When connecting NVS 460 to xDSL or Cable modem usually re...

Page 18: ...ww inscapedata com Detailed information of Installing and running IP installer can be found in IP installer user s guide 4 1 Main window of IP Installer Figure 4 1 IP Installer All the basic network p...

Page 19: ...lowings http NVS 460 IP address admin htm Example http 172 16 64 133 admin htm If you changed the HTTP port from default value you can login by typing in http NVS 460 IP address HTTP port admin htm Ex...

Page 20: ...On Screen Factory default User Name and Password are set as root and root respectively Click on OK button to enter into the Basic Setup page of Administrative Mode If you have changed the username an...

Page 21: ...Button Description Language Select a language of your choice System Name Logical name of the NVS 460 It is same as the one set up by IP installer You can reassign the system name Audio Input Selectio...

Page 22: ...o data is not transmitted if you select NA Check After you finish set up of video and audio for all the channels click on this box to obtain the possible maximum number of users Possible Max Users and...

Page 23: ...of of of of 51 51 51 51 5 3 Network Configuration Setup the network parameters appropriately in accordance with your network environment Many of the parameters in this page are same as those set up b...

Page 24: ...modem connection select this mode Refer to IP installer user s guide for Host name and domain for Cable Modem IP Assign Type Clone MAC Refer to IP installer user s guide for Clone MAC Each port should...

Page 25: ...ill in the fields with proper parameters FTP Server Setup Setup IP address Username Password and Directory of FTP server to send data in case of alarm Default FTP port number is 21 You can register th...

Page 26: ...Guide Rev 1 0 Sep 2006 26 26 26 26 of of of of 51 51 51 51 5 5 User Admin Time Setup You can change the ID and password of users and also assign different attributes for each user Figure 5 6 User Adm...

Page 27: ...ent system resource access capabilities for each of the users Attributes are Audio Bi directional Audio and Pan Tilt control For example if you want a specified user to hear the audio from the NVS 460...

Page 28: ...hronize with an Internet Time Server Synchronize the time with the internet time server at the right When the time server is out of the reach from NVS 460 you can assign time server by filling in Spec...

Page 29: ...Field Button Description Sensor 1 Select sensor type There are two types of sensors which are Normal Open and Normal Close Sensor Setup Name Input logical name for the sensor Video Capture Condition I...

Page 30: ...captured video by e mail E mail is sent to the Recv E mail address Refer to Section 5 3 Captured video data for E mail consists of intra frames only in consideration of the limited storage space for E...

Page 31: ...Small box with white background indicates the status of the relay by On Off ON On the alarm output close the relay contact Alarm Device Test OFF Off the alarm output Open the relay contact Sound Test...

Page 32: ...2 32 of of of of 51 51 51 51 Motion Check at the box at the left to allow alarm generation upon Motion detection Duration Set the duration of Alarm annunciation 10 sec 30 sec 1 min 2 min 5 min 10 min...

Page 33: ...Button Sub Field Button Description Channel Selection Not applicable Channel Sensitivity Set the sensitivity in motion detection for each channel 1 is the most sensitive and 10 is the least sensitive...

Page 34: ...colors Legend of the color red region 1 green region 2 blue region3 START Enable selection of rectangular zone start END Enable selection of rectangular zone end SELECT Click on this button and click...

Page 35: ...e can be used Setup and test the PT Pan Tilt devices Figure 5 11 PTZ Setup Field Button Sub Field Button Description Channel Selection Not applicable PTZ Model Selection Choose the PT model Refer to s...

Page 36: ...me as the PT device allows Panning Limitation SET Set the present position as left or right panning limitation Panning Limitation TEST Test the panning limitation which was set previously Preset Posit...

Page 37: ...o server You can selectively activate encryption for the video and audio data For enabling the encryption check at the box at the left of the Enable data encryption then check at the proper check boxe...

Page 38: ...button beneath GENERATE button to save the key value generated by the video server DOWNLOAD Download Key value to your PC The key values can be downloaded and stored as a file to your PC for referenc...

Page 39: ...ownloaded from Inscape Data s home page before the system upgrade is performed Refer to 6 4 How to Upgrade Your NVS 460 System Field Button Sub Field Button Description Automatic Upgrade Automatic upg...

Page 40: ...Z File Add a new PT driver software via the network PT driver can be downloaded from Inscape Data s home page Refer to 6 4 How To Upgrade Your NVS 460 System Factory Default Setting Re initialize the...

Page 41: ...41 41 41 41 of of of of 51 51 51 51 5 12 Status Report It shows you system records since the system started You can check the problems as well as the versions and event status of the whole system and...

Page 42: ...sensing devices are infrared sensors motion sensors heat smoke sensors magnetic sensor etc ALARM OUT t is used for connecting alerting device such as loud speaker flashing light etc Figure 6 1 ALARM I...

Page 43: ...s provided for connecting alarm devices or for remote on off devices such as light control Relay circuits are normal open and circuits are closed upon alarm output or remote on The relay is capable of...

Page 44: ...uppl y O pen C ol l ectorType O pen C ol l ectorType O pen C ol l ectorType O pen C ol l ectorType Photo C oupl er 3 2Connection of Relay A l arm A l arm A l arm A l arm O ut O ut O ut O ut D evi ce D...

Page 45: ...erver Example ping 192 168 1 112 If you see the Reply from message it means that the server is properly connected If you do not see a Reply message check if the network cable and power cable are prope...

Page 46: ...th is available considering the resolution and frame rate of the video Example is 704x480 video with low Max upload rate Users are recommended to adjust resolution and frame rates to lower values for...

Page 47: ...een Connect to NVS 460 in administrative mode of NVS 460 Rotate the screen by 180 degree Connect to NVS 460 Stop the connection Contrast Brightness and Volume adjustment Check the box to mute the audi...

Page 48: ...1 Save the upgrade system software to your PC Upgrade software can be downloaded from Inscape Data s home page or provided in CD 2 Log on to administrative mode and select Update Reset menu 3 Click B...

Page 49: ...51 51 51 8 After rebooting log on to the server in administrative mode again and click the Status Report 9 Check the version number and release date of the NVS 460 You can download the NVS 460 system...

Reviews: