15.1 Hardware Installation Guide
NOT FOLLOWING THIS GUIDELINE MAY VOID YOUR PRODUCT WARRANTY
Inscape Data Corporation’s next generation AirEther outdoor wireless system SB3000 & BR3000 series productrs are
high performance long range 2.4GHz and 5GHz 802.11n outdoor MIMO wireless IP networking solution. With
increased data rate capability and robust OFDM modulation, high performance reliable wireless network is possible
and supports high-demand video, voice, and data applications. When care is taken during installation and
configuration, the AirEther wireless system will operate optimally and provide long term return on your investment.
Not observing care or omitting important ground contacts during installation may degrade network performance,
cause system failure, or void the manufactures warranty. Please refer to the following table of required and
recommended accessories:
Items
Specification
Required
Notes
PoE Cable
Outdoor rated Cat 5/5e STP, FTP, ScTP
√
Shielded Twisted Pair Cable (1 to 100 meter)
PoE Port Surge
Protector
In-Line Cat 5 with 8 lines Protected or
equivalent
Strongly Recommended in severe
environment. Damage due to surge is not
covered under manufacturer warranty!
Antenna Port Surge
Protector
In-Line Coaxial Protector or equivalent
Strongly Recommended in severe
environment. Damage due to surge is not
covered under manufacturer warranty!
RJ-45 Jack
Radio/Equipment Side (Unshielded)
PoE Injector Side (Shielded)
√
Shielded RJ-45 connectors used for both ends
Ground Wire
16 AWG Copper Wire (Minimum)
√
Attached to backside of the Radio/Antenna,
Antenna mast, and appropriate common Earth
Ground. Product damage caused by improper
or no grounding is not covered under warranty!
Torque Wrench
20kgf-cm or 1.44 lbf-ft.
√
All nuts and bolts should not be tightened
beyond specified torque setting
CAT 5/5e Cable
Termination
TIA-568B Standard
√
Improper termination will damage the device
and void your warranty
Weatherproof
Sealing Tape
Rubber Mastic or equivalent
(i.e. Coax-Seal)
√
Sealing of antenna and RJ45 connector at both
end is required to ensure installation and
equipment longevity.
Summary of Contents for AirEther BR3000 Series
Page 35: ...SB3000 BR3000 Series User s Manual Rev 1 1 July 2012 35 3 6 2 Forward Reflection 3 6 3 VSWR...
Page 36: ...SB3000 BR3000 Series User s Manual Rev 1 1 July 2012 36 3 6 4 3 6 5 E Plane Field Patterns...
Page 49: ...SB3000 BR3000 Series User s Manual Rev 1 1 July 2012 49...
Page 65: ...SB3000 BR3000 Series User s Manual Rev 1 1 July 2012 65...