background image

 

 

 

 

 

INSTALLATION, SERVICE AND 

 MAINTENANCE INSTRUCTIONS 

 

ANNEX  FOR  EQUIPMENT  MARKED  CE  ATEX  UNDER  DIRECTIVE 
2014/34/EU: 

 

PROLAC HCP Ex 

 

 

The contents of this Annex supplement the information included in the instructions manual. 

The instructions included in this Annex must be observed additionally whenever equipment 

marked under Directive 2014/34/EU is used. 
This  Annex  is  to  be  supplemented  with  the  manuals  of  the  ATEX  certified  components  of 

which the assembly is comprised (e.g. motors, etc.).

 

 

 

INOXPA, S.A.U.  

Telers, 60 Aptdo. 174 

17820-Banyoles 

Tel.: +34 972 57 52 00 

Fax: +34 972 57 55 02 

[email protected] 

www.inoxpa.com

 

Original Manual 

01.030.30.03EN 

  (B) 2020/11

 

0

1

.3

0

.3

2

.0

0

01

 

Summary of Contents for PROLAC HCP Ex

Page 1: ...tions included in this Annex must be observed additionally whenever equipment marked under Directive 2014 34 EU is used This Annex is to be supplemented with the manuals of the ATEX certified components of which the assembly is comprised e g motors etc INOXPA S A U Telers 60 Aptdo 174 17820 Banyoles Tel 34 972 57 52 00 Fax 34 972 57 55 02 inoxpa inoxpa com www inoxpa com Original Manual 01 030 30 ...

Page 2: ...e danger of forming an explosive atmosphere and creating sources of combustion in potentially explosive atmospheres whereby failure to comply with those instructions may threaten your safety 1 3 GENERAL SAFETY INSTRUCTIONS 1 3 1 During the installation In order to reduce the risk of static electricity the equipment must be earthed to ensure electrical continuity between the pipes and the pump 1 3 ...

Page 3: ...ly and lawfully additionally INOXPA will be compensated for any civil liability claims submitted by third parties in the following cases besides those already described in the manual The material or equipment has been improperly used has been used negligently or has not been used according to the working conditions into classified area working in different classified area Tª and pressure condition...

Page 4: ... General Information 5 3 1 Description 5 3 2 Application 5 4 Installation 6 4 1 Reception of the pump 6 4 2 Transport and storage 6 4 3 Location 6 4 4 Pipes 6 4 5 Pressurization tank 7 4 6 Electrical installation 7 5 Starting the pump 8 6 Maintenance 9 6 1 General Considerations 9 6 2 Cleaning 9 6 3 Assembly disassembly of the pump 10 7 Technical Specifications 11 ...

Page 5: ...his pump was selected for a given set of pumping conditions and operating conditions under explosive atmospheres when the order was placed INOXPA shall not be liable for any damage resulting from the incompleteness or inaccuracy of the information provided by the purchaser nature of the fluid viscosity RPM class of the potentially explosive area gas generated by the potentially explosive atmospher...

Page 6: ...fety indications must be observed The motors used must be EC marked in accordance with Directive ATEX 2014 34 EU and with the instructions of the manufacturer and the applicable national and local regulations When pumping inflammable or explosive liquids a proper connection must be used Connect the parts of the assembly with the earth connections in order to reduce the risk of static electricity D...

Page 7: ... at all times The motor must also be fitted with overload protection devices suited to its rated power If necessary install a separate fan bearing in mind the environment where it will operate potentially explosive atmosphere The electrical equipment the terminals and the components of the control systems may still bear electrical current when powered off Contact with them can be dangerous for the...

Page 8: ... qualified or trained personnel as specified by EU Directive ATEX 2014 34 EU 5 1 1 Checks before starting the pump Before starting up the pump make sure that the suction and discharge valves of the pump are open If there is a risk that the pump is operated in vacuum i e with no fluid it is recommended that a flow detection sensor is fitted in the suction side of the pump or any other device preven...

Page 9: ...ed area it must be expressly stated that the pump is an ATEX pump and the manufacture number must be quoted Otherwise INOXPA cannot ensure that the pump will operate with parts that are suitable for the classified area within which it is installed 6 1 1 Check the mechanical seal Check areas 1 and 21 daily Check areas 2 and 22 weekly For a Double mechanical seal A control of temperature level and b...

Page 10: ...ASSEMBLY DISASSEMBLY OF THE PUMP Improper assembly or disassembly of the equipment can impair operation of the pump cause high repair costs long downtime and even render the protective system of the equipment ineffectual INOXPA disclaims any responsibility for accidents or damage caused by failure to observe the instructions of the manual and of this Annex In addition to the instructions included ...

Page 11: ...ture may be exceeded This is why a simple mechanical seal must not operate under any circumstances in dry conditions Regularly check that the single mechanical seal is functioning correctly Check that the hydraulic part of the pump is always free of liquid during operation Avoid pumping fluids that contain large amounts of gas The client must use a flow meter flow detector or any other safety devi...

Page 12: ...the sealing system may have leaks in the middle or be open due to insufficient backpressure of the washing liquid b Simple mechanical seal thermosensor balanced The instructions of the mechanical seal manufacturer and in particular those concerning the temperature probe must be followed at all times ...

Page 13: ......

Page 14: ...NOTAS ...

Page 15: ...NOTAS ...

Page 16: ...NOTAS ...

Page 17: ...SKANDINAVIEN A S DENMARK Tel 45 76286900 inoxpa dk inoxpa com SWEDEN Tel 031 336 05 60 inoxpa se inoxpa com INOXPA ITALIA S R L VENEZIA Tel 39 041 411236 inoxpa it inoxpa com INOXPA UK LTD KENT Tel 01737 378060 inoxpa uk inoxpa com INOXPA Solutions Moldova CHISINAU Tel 373 69 102 624 info gmp moldova com INOXRUS САНКТ ПЕТЕРБУРГ Teл 7 812 622 16 26 spb inoxpa com МОСКВА Тел 7 495 120 26 17 moscow i...