4.Installation 

 

Before  closing  the  suction  and  discharge  valves,  make  sure  that  the  pump  is 
switched-off and has stopped.

 

 
 

4.4.1.  

 

Shut-off valves 

 

Use valves that are EC marked in accordance with the Directive ATEX 2014/34/EU 
and  in  accordance  with  the  manufacturer's  instructions  and  the  applicable 
national and local regulations. 

 
 

4.5. 

 

PRESSURIZATION TANK 

 

A pressurisation tank for double mechanical seals must always be pressurised at 

between  1.5  and  2.0  bar  over  the  operating  pressure  of  the  pump  when  it  is 
functioning, even when it is in operation or stopped. See instruction manual for 

the mechanical seal and pressurisation container. Check that the instrumentation 
leading to the pressurisation tank is appropriate for the work area.

 

 

4.6. 

 

ELECTRICAL INSTALLATION 

Before connecting an electric motor to the system, check local regulations regarding electric safety and 
standards EN 60204-1 and EN 60079-14. Also the motor manual. 

This motor should be Atex with adequate 

protection for the working environment in which it must run. 

 
 

Follow the motor manufacturer's indications at all times. 

 
 

The motor must also be fitted with overload-protection devices suited to its rated 
power. 

 

If  necessary,  install  a  separate  fan,  bearing  in  mind  the  environment  where  it  will  operate  (potentially 
explosive atmosphere). 
 

The electrical equipment, the terminals and the components of the control systems 

may  still  bear  electrical  current  when  powered  off.  Contact  with  them  can  be 
dangerous for the operator and the equipment or cause irreparable damage to the 

material. The instructions of the manufacturer must be followed strictly in order 
to open the motor safely. 

 

Safe-work  permits  shall  be  required  to  handle  the  equipment  in  potentially 
explosive  atmospheres.  It  is  strongly  recommended  that  this  type  of  work  is 

carried  out  in  non-classified  atmospheres  (i.e.  there  must  not  be  an  explosive 
atmosphere in the location of the pump when it is being handled). 

 

Air  must  be  recirculated  to  cool  the  pump  motor.  Check  that  there  is  no  other 

equipment or surface which may emit additional heat or affect the cooling of the 
motor. See the instruction manual of the motor. 

 

The turning direction must be set when the motor is disconnected from the pump, 

or  when  pump  is  completely  primed  and,  in  the  case  of  pressurised  cooled  or 
double mechanical seals, the seal chamber is filled with liquid.

 

Summary of Contents for PROLAC HCP Ex

Page 1: ...tions included in this Annex must be observed additionally whenever equipment marked under Directive 2014 34 EU is used This Annex is to be supplemented with the manuals of the ATEX certified components of which the assembly is comprised e g motors etc INOXPA S A U Telers 60 Aptdo 174 17820 Banyoles Tel 34 972 57 52 00 Fax 34 972 57 55 02 inoxpa inoxpa com www inoxpa com Original Manual 01 030 30 ...

Page 2: ...e danger of forming an explosive atmosphere and creating sources of combustion in potentially explosive atmospheres whereby failure to comply with those instructions may threaten your safety 1 3 GENERAL SAFETY INSTRUCTIONS 1 3 1 During the installation In order to reduce the risk of static electricity the equipment must be earthed to ensure electrical continuity between the pipes and the pump 1 3 ...

Page 3: ...ly and lawfully additionally INOXPA will be compensated for any civil liability claims submitted by third parties in the following cases besides those already described in the manual The material or equipment has been improperly used has been used negligently or has not been used according to the working conditions into classified area working in different classified area Tª and pressure condition...

Page 4: ... General Information 5 3 1 Description 5 3 2 Application 5 4 Installation 6 4 1 Reception of the pump 6 4 2 Transport and storage 6 4 3 Location 6 4 4 Pipes 6 4 5 Pressurization tank 7 4 6 Electrical installation 7 5 Starting the pump 8 6 Maintenance 9 6 1 General Considerations 9 6 2 Cleaning 9 6 3 Assembly disassembly of the pump 10 7 Technical Specifications 11 ...

Page 5: ...his pump was selected for a given set of pumping conditions and operating conditions under explosive atmospheres when the order was placed INOXPA shall not be liable for any damage resulting from the incompleteness or inaccuracy of the information provided by the purchaser nature of the fluid viscosity RPM class of the potentially explosive area gas generated by the potentially explosive atmospher...

Page 6: ...fety indications must be observed The motors used must be EC marked in accordance with Directive ATEX 2014 34 EU and with the instructions of the manufacturer and the applicable national and local regulations When pumping inflammable or explosive liquids a proper connection must be used Connect the parts of the assembly with the earth connections in order to reduce the risk of static electricity D...

Page 7: ... at all times The motor must also be fitted with overload protection devices suited to its rated power If necessary install a separate fan bearing in mind the environment where it will operate potentially explosive atmosphere The electrical equipment the terminals and the components of the control systems may still bear electrical current when powered off Contact with them can be dangerous for the...

Page 8: ... qualified or trained personnel as specified by EU Directive ATEX 2014 34 EU 5 1 1 Checks before starting the pump Before starting up the pump make sure that the suction and discharge valves of the pump are open If there is a risk that the pump is operated in vacuum i e with no fluid it is recommended that a flow detection sensor is fitted in the suction side of the pump or any other device preven...

Page 9: ...ed area it must be expressly stated that the pump is an ATEX pump and the manufacture number must be quoted Otherwise INOXPA cannot ensure that the pump will operate with parts that are suitable for the classified area within which it is installed 6 1 1 Check the mechanical seal Check areas 1 and 21 daily Check areas 2 and 22 weekly For a Double mechanical seal A control of temperature level and b...

Page 10: ...ASSEMBLY DISASSEMBLY OF THE PUMP Improper assembly or disassembly of the equipment can impair operation of the pump cause high repair costs long downtime and even render the protective system of the equipment ineffectual INOXPA disclaims any responsibility for accidents or damage caused by failure to observe the instructions of the manual and of this Annex In addition to the instructions included ...

Page 11: ...ture may be exceeded This is why a simple mechanical seal must not operate under any circumstances in dry conditions Regularly check that the single mechanical seal is functioning correctly Check that the hydraulic part of the pump is always free of liquid during operation Avoid pumping fluids that contain large amounts of gas The client must use a flow meter flow detector or any other safety devi...

Page 12: ...the sealing system may have leaks in the middle or be open due to insufficient backpressure of the washing liquid b Simple mechanical seal thermosensor balanced The instructions of the mechanical seal manufacturer and in particular those concerning the temperature probe must be followed at all times ...

Page 13: ......

Page 14: ...NOTAS ...

Page 15: ...NOTAS ...

Page 16: ...NOTAS ...

Page 17: ...SKANDINAVIEN A S DENMARK Tel 45 76286900 inoxpa dk inoxpa com SWEDEN Tel 031 336 05 60 inoxpa se inoxpa com INOXPA ITALIA S R L VENEZIA Tel 39 041 411236 inoxpa it inoxpa com INOXPA UK LTD KENT Tel 01737 378060 inoxpa uk inoxpa com INOXPA Solutions Moldova CHISINAU Tel 373 69 102 624 info gmp moldova com INOXRUS САНКТ ПЕТЕРБУРГ Teл 7 812 622 16 26 spb inoxpa com МОСКВА Тел 7 495 120 26 17 moscow i...

Reviews: