Over 68ºC the operator should take protective measures and place warning notices
advising of the danger which exists if the blender is touched.
The type of protection selected should not isolate the blender entirely.
5.5. PIPES
About the installation pipes:
- As a general rule, install the suction and discharge lines in straight sections, with the minimum
possible number of elbows and fittings to reduce any pressure losses that may be caused by
friction.
- Make sure that the blender’s ports are properly aligned with the pipework and have a diameter
similar to that of the blender connections.
- Place the blender as close as possible to the suction tank and whenever possible below the
liquid level in order to achieve its priming .
- Install support brackets for the lines as close as possible to the blender’s suction and discharge
ports.
5.5.1.
Shut-off valves
The blender may be isolated for maintenance. To accomplish this, shut-off valves must be installed
and connected to the blender’s suction and discharge connections.
5.6. ELECTRICAL INSTALLATION
Only qualified personnel can connect the electric motors.
Take the necessary measures to prevent damage to cables and connections.
Electrical equipment, terminals and components of the control systems may still carry
current when they are disconnected. Contacting them may impose a hazard to operators
or cause irreparable material damage.
Before handling the blender make sure that the motor is stopped.
To do the electrical installation:
- connect the motor in accordance with the instructions
supplied by the motor manufacturer, in accordance with
the current national legislation and in compliance with EN
60204-1,
-
check the direction of rotation (see the signalling label on
the blender),
- start and stop the blender motor momentarily. Make sure,
looking at the blender by the hopper side, that the rotation
direction of the motor fan is counterclockwise.
ALWAYS check the direction of rotation of the motor with liquid inside the blender.
ATTENTION
02.020.32.0005
These valves must ALWAYS be open during operation of the mixer.
ATTENTION
Installation
11
INOXPA S.A.U.
02.020.30.02EN · (0) 2022/02