background image

FA130 Keypad 

 

The FA130 keypad is a 900MHz wireless transmitter used to arm and disarm 
the Vision Plus™ or Wireless Guardian™ system. The FA130 is a one-way 
device, which can be programmed as a supervised point. Functionally, the 
FA130 emulates the KP130 hardwire executive keypad, without the LCD 
display. 

 

PROGRAMMING THE KEYPAD: 

 

1.  If desired, identify the point number of the unit with numbered labels 

provided with the Vision Plus™ or Wireless Guardian™ panel. 

2.  Turn the phillips-head screw on the bottom of the housing slightly. 

Separate the housing halves. 

3.  Complete program data entry as shown below Figure 1. When prompted 

to "Plug in Xmitter", connect the programming cable between 
programming headers on the hardwire executive keypad and the FA130 
wireless keypad. Refer to Figure 2 to locate the programming header. 

4.  Press the reset button on the FA130 keypad. When programming has 

been confirmed by the hardwire executive keypad, disconnect the 
programming cable. 

5.  Test the FA130. Pressing any arming key will cause the keypad to 

transmit and the transmit LED under the ENTER key to flash during 
transmissions. The panel will decode the message to determine if it is 
valid. 

6.  Mount the keypad using hardware provided. 

 

3.

0V

+

RESET BUTTON

PROGRAMMING

HEADER

TRANSMIT LED

(SURFACE MOUNT CHIP)

 

Figure 2: FA130 programming 

 
 
 
 
 
 

MOUNTING THE FA130

 

1.  Turn the phillips-head screw on the bottom of the housing one turn. 

Separate the housing halves. 

2.  Use supplied hardware to attach the FA130 securely to a  wall. 

3.  Use the mounting holes in the backplate as needed to locate screws or 

wall anchors.  

 
 
 

 

 

MOUNTING HOLES

(4 PLACES)

 

Figure 3: back housing mounting holes 

Summary of Contents for FA130

Page 1: ...ed programming Type KEYPAD Monitored No Not Applicable Audible No Not Applicable Relay out No Not Applicable Recommended Check in 30 seconds Typical battery life 3 4 years Battery type BAT604 Duracell DL123A 3V Low battery monitoring automatic Programmed check in values are executed at 3 times the interval shown to extend battery life For example 30 seconds results in a 90 second check in interval...

Page 2: ...cutive keypad and the FA130 wireless keypad Refer to Figure 2 to locate the programming header 4 Press the reset button on the FA130 keypad When programming has been confirmed by the hardwire executive keypad disconnect the programming cable 5 Test the FA130 Pressing any arming key will cause the keypad to transmit and the transmit LED under the ENTER key to flash during transmissions The panel wi...

Page 3: ... Figure 4 Arming Status Tones OTHER STATUS TONES The Vision Plus or Wireless Guardian system will generate status tones from the hardwire executive keypad and the audio output as shown in Figure 5 ALARM ON SENSOR PROGRAMMED AUDIBLE YES ENTRY or EXIT CHIME FIRE ALARM OR KEYPAD FIRE ALARM SENSOR INACTIVE OR LOW BATTERY 7 SECOND INTERVAL SYSTEM NOT READY WHEN ARMING DELAY SENSOR TR 2 SECOND INTERV AL...

Page 4: ...nics products This warranty does not warrant the replacement of batteries that are used to power Inovonics Products The User recognizes that a properly installed and maintained security system may only reduce the risk of events such as burglary robbery personal injury and fire It does not insure or guarantee that there will be no death personal damage and or damage to property as a result Inovonic...

Page 5: ......

Reviews: