-225-
7 Control Mode
7
U
NBYNPUPSTQFFE
NBYQSP珝MFWFMPDJUZ 'I
NJNBYQSP珝MFWFMPDJUZ 'I
NJNBYNPUPSTQFFE
☆ Related parameters
Index
607Fh
Name
Max profile velocity
Setting
Condition
& Effective
Time
During
running &
Immediately
Data
Structure
VAR
Data
Type
UINT32
Access
RW
Mapping
RPDO
Related
Mode
PP/PV/PT/HM/
CST
Value
Range
0 to (2
32
–1)
(velocity
unit/s)
Default 104857600
Defines the speed limit in PP, PV, PT, HM and CST modes.
5
Acceleration limit
In the homing mode, the change rate of the position reference can be limited through the acceleration
limit.
☆ Related parameters
Index
60C5h
Name
Max. acceleration
Setting
Condition
& Effective
Time
During
running &
Immediately
Data
Structure
VAR
Data
Type
Uint32
Access
RW Mapping
RPDO
Related
Mode
All
Value
Range
0 to
4294967295
(acceleration
unit/s
2)
Default 2147483647
Defines the maximum limit of acceleration.
In the homing mode, if the value of 6083h exceeds that of 60C5h, the value of 60C5h will be used.
For 60C5h, the set value 0 will be forcibly changed to 1.
7.9.4 Homing Operation
■
Homing mode
1)
6098h = 1
Mechanical home: Z signal
Deceleration point: negative limit switch (N-OT)