background image

Version 1.4  

 

 

 

                              Page 3 

1.

 

INTRODUCTION

 

Thank

 

you

 

for

 

your

 

purchase

 

of

 

the

 

Wireless

 

Pool

 

Thermometer

 

with

 

time,

 

date,

 

and

 

indoor

 

temperature.

 

The

 

following

 

user

 

guide

 

provides

 

step

 

by

 

step

 

instructions

 

for

 

installation,

 

operation

 

and

 

troubleshooting.

   

 

IMPORTANT

 

NOTES:

 

 
‐ 

ONLY

 

INSTALL

 

IN

 

FRESH

 

WATER.

 

DO

 

NOT

 

INSTALL

 

IN

 

SALT

 

WATER.

   

   
‐ 

DO

 

NOT

 

EXCEED

 

THE

 

OPERATIONAL

 

RANGE

 

(

40

 

°F

 

TO

 

140

 

°F)

 

 

2.

 

GETTING

 

STARTED

 

The

 

Wireless

 

Poo

 

Thermometer

 

consists

 

of

 

a

 

display

 

station

 

(receiver),

 

and

 

a

 

wireless

 

thermometer

 

(remote

 

transmitter).

 

2.1

 

 

Parts

 

List

 

QTY

 

Item

 

1

 

Display

 

station

   

/

 

Dimensions

 

:

 

119x74x21mm

 

1

 

Pool

 

Thermometer

 

transmitter /

 

Dimensions:

 

ø80mmx160mm

1

 

User

 

Manual

 

2.2

 

Remote

 

Pool

 

Thermometer

 

Sensor

 

Set

 

Up

 

Note:

 

To

 

avoid

 

permanent

 

damage,

 

please

 

take

 

note

 

of

 

the

 

battery

 

polarity

 

before

 

inserting

 

the

 

batteries.

 

 

1.

 

Twist

 

off

 

the

 

transmitter

 

cover

 

(counterclockwise),

 

as

 

shown

 

in

 

Figure

 

1.

   

Be

 

careful

 

not

 

to

 

stress

 

the

 

sensor

 

wire.

 

 

 

Figure

 

1

 

 
 

2.

 

Insert

 

two

 

AA

 

batteries

 

and

 

close

 

the

 

battery

 

door,

 

as

 

shown

 

in

 

Figure

 

2.

 

 

Summary of Contents for SP03

Page 1: ...Version 1 4 Page 1 WIRELESS POOL THERMOMETER Ref SP03 User s manual ...

Page 2: ... Time 8 4 2 3 Set Date 8 4 3 Alarm Mode 8 4 3 1 Activating Deactivating the Alarm 8 4 3 2 Cancelling the Alarm 8 4 3 3 Snooze Alarm 8 4 4 Min Max Mode 8 4 5 C F Units of Measure 9 4 6 Multi Channel Operation 9 4 6 1 Multi channel Sensor Initialization 9 4 6 2 Multi channel Sensor Accuracy Note 9 4 7 Maintenance 9 5 GLOSSARY OF TERMS 9 6 SPECIFICATIONS 10 6 1 Wireless Specifications 10 6 2 Measurem...

Page 3: ...e Wireless Poo Thermometer consists of a display station receiver and a wireless thermometer remote transmitter 2 1 Parts List QTY Item 1 Display station Dimensions 119x74x21mm 1 Pool Thermometer transmitter Dimensions ø80mmx160mm 1 User Manual 2 2 Remote Pool Thermometer Sensor Set Up Note To avoid permanent damage please take note of the battery polarity before inserting the batteries 1 Twist of...

Page 4: ...nge Dip Switches 1 and 2 as referenced in Table 1 5 Temperature Units of Measure To choose the transmitter display units of measure F C change Dip Switch 3 as referenced in Table 1 DIP SWITCH FUNCTION 1 2 3 DOWN DOWN Channel 1 factory default setting UP DOWN Channel 2 DOWN UP Channel 3 DOWN F UP C factory default setting Table 1 6 Verify the correct channel number CH and temperature units of measu...

Page 5: ... 1 5V alkaline or lithium avoid rechargeable batteries in the back of the display console All of the LCD segments will light up for a few seconds to verify all segments are operating properly and the unit will beep Replace the battery door and fold out the desk stand and place the console in the upright position The console will instantly display indoor temperature and the default date and time Th...

Page 6: ...Layout Note The following illustration shows the full segments of the receiver LCD for description purposes only and will not appear like this during normal operation Figure8 1 Transmitter channel number 2 Water temperature units F C 3 Water temperature 4 Indoor temperature units F C 5 Indoor temperature 6 Time and snooze alarm 7 Time of day 8 Date 9 Day of week 10 Min max icon 11 Transmitter rece...

Page 7: ...ing buttons and location 1 MODE on the back of the display 2 C F on the back of the display 3 MAX MIN on the back of the display 4 SET on the back of the display 5 CHANNEL on the top of the display 6 CLEAR on the top of the display 4 2 Set Program Mode Press the MODE button to switch between TIME ALARM DATE The following section defines how to set the time alarm and date Notes After 60 seconds of ...

Page 8: ... the day 4 Press the SET button again to return to normal mode 4 3 Alarm Mode 4 3 1 Activating Deactivating the Alarm 1 While in the ALARM mode press the C F button to activate the alarm The alarm icon will appear 2 Press the C F button again to deactivate the alarm The alarm icon will disappear 4 3 2 Cancelling the Alarm When an alarm has been triggered the alarm will sound and the alarm icon wil...

Page 9: ...wer up the second remote thermometer and set the channel number dip switches as described in Section 2 3 Verify the display reads Channel 2 3 Power up the third remote thermometer if available and set the channel number dip switches as described in Section 2 3 Verify the display reads Channel 3 4 Power up the console last and wait about 3 minutes Press the CHANNEL button on the top of the display ...

Page 10: ...nths for base station Minimum 12 months for remote thermometer sensor use lithium batteries in cold water climates 7 TROUBLESHOOTING GUIDE Problem Solution Wireless remote not reporting in to station The maximum line of sight communication range is 100m Move the display console closer to the remote sensor Cycle power on the station by removing and re inserting the batteries The station may have ex...

Page 11: ... alkaline batteries that last longer than the saline batteries and when possible rechargeable batteries deposit batteries and accumulators in specific containers arranged among traders For example metals will be valued and polluted the environment because they contain heavy metals hazardous to health and the environment primarily cadmium and nickel The piles must installation by respecting the pol...

Page 12: ... 12 instructions are complied with or to make himself the replacement of batteries If a battery is swallowed immediately consult a doctor or poison control center nearest you Do not forget to carry the product with you ...

Reviews: