11
GB
Ground connections and equipotential bonding
• The appliance must be connected to the ground
circuit using the terminals marked by the symbol
located next to the connection terminals.
• The metal structure of all the electrical appliances
must also be connected to the ground circuit using
the terminals marked by the symbol
located
next to the earth terminals (equipotential bonding
system).
SETTING UP
Testing the electrical system
• Switch on the appliance following the instructions
for use and cheek the operation of the control
devices and well heating elements.
• Test the various operating temperatures.
• The appliance is fitted with an internal safety
thermostat for each well that cuts off the electrical
power supply to the heating elements if the main
thermostat malfunctions.
• If necessary, consult the Troubleshooting guide to
identify the problem.
Testing the rated thermal power
• Always cheek the thermal power of the appliance
after installation and following maintenance work.
• The rated thermal power is indicated in the
“Technical data” table.
TROUBLESHOOTING GUIDE
The well heating elements do not heat up
• Check the fuses.
• Main power switch not ON.
• Low voltage or incorrect electrical connection.
• Switch faulty.
• Temperature control thermostat faulty.
• Main temperature control thermostat faulty, causing
the safety thermostat to cut in (reset).
• One or more well heating elements incorrectly
connected or burnt out (replace faulty heating
element).
The temperature control is difficult or impossible
to regulate
• Temperature control thermostat faulty.
• One or more well heating elements incorrectly
connected or burnt out (replace faulty heating
element).
REPLACEMENT OF SPARE PARTS
IMPORTANT : Before carrying out maintenance work
or repairs, disconnect the appliance from the power
supply at the isolating switch.
Temperature control thermostat, safety thermo-
stat and switch
• Remove the upper control panel.
• Open the appliance doors and drain the oil from the
well in question (see “Draining off the oil”).
• Detach the bulb from the thermostat fixed to the
heating element by special support brackets.
• Disconnect the electrical connections.
• Replace the part.
Summary of Contents for 7FE100-200
Page 2: ......
Page 4: ......
Page 5: ...Elektrikli Frit z Electric Fryer...
Page 6: ...4 700 SER 700 SERIES 700 900 SER 900 SERIES 900 E E...
Page 7: ...5 ekil 1 Figure 1 1 ekil 2 Figure 2 2 700 900...
Page 16: ...14 7FE100 9FE100 ELEKTR K EMASI ELECTRIC SCHEMA...
Page 17: ...15 7FE200 9FE200 ELEKTR K EMASI ELECTRIC SCHEMA...
Page 18: ......
Page 19: ...Elektrikli Patates Dinlendirici Electric Frenc Fry Warmer...
Page 20: ...18 E...
Page 21: ...19 ekil 1 Figure 1 1 ekil 2 Figure 2 2 700 900...
Page 27: ...25 7HE100 ELEKTR K EMASI ELECTRIC SCHEMA X Q D H 500...
Page 28: ...26 1 2...
Page 29: ...27 7HE100 730 400 230 0 5 220 230 50 60 19...
Page 30: ...28 1 Henkel Helios 4 2 220 230 50 60 10...
Page 31: ...29 1 1 x 150 1 0 0...
Page 32: ...30 7HE 100...