LOW SALT 

The es mated salt concentra on is lower than the op mum working range. The unit will remain in ON state 
and chlorine produc on will con nue normally. This message can also be displayed if the water is too cold, 
the electrodes are worn‐out or calcium has built up on the electrodes.    

 
SALT TOO LOW 

The es mated salt concentra on too low and out of the working range. The system will stop the produc on 
to avoid damage to the cell. This message can also appear if the cell is not properly connected. Press OK to 
confirm the message. The system will stop displaying the message and the unit will go to OFF state.  Once the 
problem has been solved, the user can turn the unit ON again.  
 

PAUSE 04:54  

When the system is carrying out a polarity inversion, the unit enters a pause mode and the remaining  me is 
displayed  on the screen. 

 

 

8. MENUS 

 

To enter the menus, press the MENU key and move up or down between the different sub‐menus using the 

 

 keys. To enter a par cular sub‐menu press OK. Once in a sub‐menu  use 

 o 

 to change a parameter, 

MENU  to  go  to  the  next  parameter  and  OK  to  confirm  and  save  changes.  Then,  use  MENU  once  or  more 

mes to come back to the Main Screen. 

 

8.1 Func ons menu 
 

8.1.1 Language 

 

Select the language and press 

OK. 

 
8.1.2. LCD Contrast 

This menu is no longer implemented . In order to be able to adjust the contrast even when an incorrect 
se ng  does  not  allow  to  read  the  screen,  a  poten ometer  marked  with  “

CONTRASTE” 

has  been 

mounted on the PCB, in the reverse side of the display. If you need to adjust the contrast, open the 
cabinet door and use a small screwdriver to turn it slowly un l the contrast is OK. 

8.1.3. Readings 

This is an only‐read screen that provides a list of system measurements. These values are used for di‐
agnose in technical support. 

 
8.1.4. 4‐20 mA Control 
 

Ac vate or deac vates the 4‐20 mA external control. 

 

8.1.5. pH Adjustment —op on 

Follow the instruc ons joined when the pH op on has been included. 
 
 

8.2 Status menu 

This is an only‐read screen that provides a list of system measurements. These values are used for diagnose 
in technical support. 

Summary of Contents for SMC50

Page 1: ...r The unit must impera vely be protected by a 30 mA residual current circuit breaker Only qualified and authorized personnel should open the electrical cabinet Risk of electrical shock or fire hazard 230VAC The unit must impera vely be installed a er the filter and must be the last element the wa ter passes through before returning to the poll ...

Page 2: ...el installa on 5 4 Cell installa on 5 Cell housing Electrode assembly Flow switch Celle leads 5 Pump commissioning 6 6 Electrical connec ons 7 6 Opera on 7 6 1 Screen indica ons 6 2 ON OFF switching 6 3 ON state produc on 7 Display messages 9 8 Menus 10 9 Regular maintenance 11 10 Warnings 12 ...

Page 3: ... electroly c proceeds could break the cell and eventually explode Do not install the cell before the filter or any other element The cell must be the last element the wa ter passes through before returning to the pool Otherwise the gas generated in the cell could build up in the circuit and cause an explosion Install the unit in a fresh and well ven lated area and protected from flooding and liquid ...

Page 4: ...once the water has passed through the filter and through any other element and just before the return to the pool When passing through the cell the water acquires a high and very effec ve chlorine concentra on capable of destroying most contaminants The SMC75 main elements are 1 Power and control cabinet It houses the control and power units 2 Control keyboard and display 3 Cell housing Its holds th...

Page 5: ...uding stainless steal and destroy electronic circuits Keep the top of the panel and the heat sink area clear of any objects 4 CELL INSTALLATION Cell housing The chlorinator must be fed with filtered water Install the cell housing by means of a by pass at the end of the return water flow once the water has passed through the filter and through any other element and just before the return to the pool S...

Page 6: ... loose the flow switch in order to evacuate the air inside Once the cell tubes are completely filled don t forget to re ghten the flow switch Verify that the arrow marking on the flow switch corre sponds to the water flow direc on a er re ghtening Water must flow at sufficient speed trough the cell If the flow is too low scale could build on the electrodes If the installa on is not provided with a dedicate...

Page 7: ...der to control the chlorinator produc on cycles use the External Control Cable Disconnect the power supply only when you are not going to use the chlorinator or in case of fault The chlorinator must impera vely be connected to a protec ve earth through its power supply cable and protected by a 30 mA residual circuit breaker External Control Cable The two wire cable marked EXTERNAL CONTROL 230VAC i...

Page 8: ...ure Water Water sensor state when not implemented Cext External control signal signal read by the External Control Cable Flow Indicates the state of the flow switch 6 2 Switching the unit ON and OFF To alterna vely switch the unit ON and OFF make sure you are in the main Screen and press the MENU ON OFF key for about two seconds If the display was not in the Main Screen you can always come back to ...

Page 9: ... When the External Control Cable signal is OFF 0 VAC between its wires the Cext reading turns OFF and the chlorine produc on is halted un l the signal turns on again This pausing state is also indicated on the screen bo om line with the message CONTROL EXT OFF Be aware that even if the produc on is halted the unit is s ll in ON state 7 DISPLAY MESSAGES The bo om line of the screen is used to indic...

Page 10: ...sing the keys To enter a par cular sub menu press OK Once in a sub menu use o to change a parameter MENU to go to the next parameter and OK to confirm and save changes Then use MENU once or more mes to come back to the Main Screen 8 1 Func ons menu 8 1 1 Language Select the language and press OK 8 1 2 LCD Contrast This menu is no longer implemented In order to be able to adjust the contrast even wh...

Page 11: ...ness is very high even a fast flow won t prevent the scale from building up If this occurs decrease the polarity period and make sure the water pH stays close to 7 0 The polymer seal under the cell cap and the protec ve sleeves of the electrode rods must both be intact If any damage is observed send the cell to the technical service for inspec on and recondi oning The electrodes of the SMC75 cell h...

Page 12: ...ell and eventually explode NEVER install the chlorinator before the filter or any other element The chlorinator must be the last element the water passes through before returning to the pool Otherwise the gas generated in the cell could build up in the circuit and cause an explosion DO NOT access the Programme menu or change any parameter in it ALWAYS keep the cell caps cell terminals and cell conn...

Reviews: