10
Rev. 15‐03‐2017
LOW SALT
The es mated salt concentra on is lower than the op mum working range. The unit will remain in ON state
and chlorine produc on will con nue normally. This message can also be displayed if the water is too cold,
the electrodes are worn‐out or calcium has built up on the electrodes.
SALT TOO LOW
The es mated salt concentra on too low and out of the working range. The system will stop the produc on
to avoid damage to the cell. This message can also appear if the cell is not properly connected. Press OK to
confirm the message. The system will stop displaying the message and the unit will go to OFF state. Once the
problem has been solved, the user can turn the unit ON again.
PAUSE 04:54
When the system is carrying out a polarity inversion, the unit enters a pause mode and the remaining me is
displayed on the screen.
8. MENUS
To enter the menus, press the MENU key and move up or down between the different sub‐menus using the
↓
↑
keys. To enter a par cular sub‐menu press OK. Once in a sub‐menu use
↓
o
↑
to change a parameter,
MENU to go to the next parameter and OK to confirm and save changes. Then, use MENU once or more
mes to come back to the Main Screen.
8.1 Func ons menu
8.1.1 Language
Select the language and press
OK.
8.1.2. LCD Contrast
This menu is no longer implemented . In order to be able to adjust the contrast even when an incorrect
se ng does not allow to read the screen, a poten ometer marked with “
CONTRASTE”
has been
mounted on the PCB, in the reverse side of the display. If you need to adjust the contrast, open the
cabinet door and use a small screwdriver to turn it slowly un l the contrast is OK.
8.1.3. Readings
This is an only‐read screen that provides a list of system measurements. These values are used for di‐
agnose in technical support.
8.1.4. 4‐20 mA Control
Ac vate or deac vates the 4‐20 mA external control.
8.1.5. pH Adjustment —op on
Follow the instruc ons joined when the pH op on has been included.
8.2 Status menu
This is an only‐read screen that provides a list of system measurements. These values are used for diagnose
in technical support.