 SPECIFICATIONS : -

v

The Controller in its installed state should not be 

 

voltage sensor input.

v

  The controller is generally part of control panel and in 

 

to the user after installation.

 

heat.

 

must comply with local electrical regulation.

 

the controller must not exceed the maximum specified 

 

such a case the terminals should not remain accessible 

 

loads might create momentary Fluctuation in display, 

 

such supply could rise above 264 VAC which will damage 

 

voltage DC and sensor input must be routed away from 

 

the controller.

 

close proximity to any corrosive/combustible gases, 

 

it may lead personnel injury.

 

caustic vapors, oils, steam or any other process by-

v

The controller in its installed state must be protected 

 

with unearthed star connection. Under fault condition 

v

Ambient temperature and relative humidity surrounding 

 

this, use shielded ground at both ends.

It is essential to install a over Temp. Protection device to 

v

The controller must be wired as per wiring diagram & it 

 

from any possible damage due to short circuit on loads.

 

high current power cables. Where it is impractical to do 

 

protect the controller from any possible damage due to 

 

against excessive electrostatic or electromagnetic 

v

The controller should not be wired to a 3-Phase supply 

 

hence should not be obstructed in the panel.

v

The Controller in its installed state must not come in  

 

limit for proper operation of the   controller.

 

products.

 

interferences. Ventilation holes provided on the chassis 

 

of the instrument are meant for thermal dissipation 

 

MECHANICAL

 

exposed to carbon dust, salt air, direct sunlight or radiant 

 

ELECTRICAL

v

Care must be taken not to connect AC supplies to low 

 

installed between power supply and supply terminals to 

v

Circuit  breaker  and  appropriate  fuses  must be used 

 

for  driving high voltage loads to protect the controller 

v

The Electrical noise generated by switching inductive 

v

Circuit breaker or mains s/w with fuse (275V/1A) must be 

 

high voltage surges of extended duration.

v

To minimize pickup of electrical noise, the wiring for low 

 

To reduce this use snubber circuit across  the load.

 

the product, this could damage the process being 

 

alarm latch up, data loss or permanent damage to the 

 

instrument. 

 

avoid any failure of heating system. Apart from spoiling 

 

controlled.

 

This controller is meant for temperature control 

 

applications. It is important to read the manual prior to 

 

related instruction appearing in this manual must be 

 

followed to ensure safety of the operating personnel 

 

GENERAL

 

operation. Incorrect configuration could result in 

 

damage to the equipment or the process under control or 

 

installing or commissioning of controller. All safety 

 

SAFETY INSTRUCTION :

 

as well as the instrument.

v

  The controller must be configured correctly for intended 

1

USER’S  OPERATING  MANUAL  FOR  PID  DIGITAL  TEMPERATURE  CONTROLLER

OIM Px-X18

e

 V2.1 Page 1 of 5

e

e

(Models: Px 418  / 718  )

 

 

 

 

   4 Digit Bright White (PV)

2. INPUT

 

 

 

 

    T 

 : Tunning Stauts

    Sensor inpu  

 

 : TC : J, K, RTD : Pt-100

4. SSR DRIVE OUTPUT

    Digital Filter                             : 1 to 10 Sec.

    STATUS LED’S 

 

 : 1 

: Control Output Status

    Operating Range 

 

 : 0 ~50°C, 5~90% Rh

    Drive Capacity 

 

 : 12V @ 30mA.

7. POWER SUPPLY

    Contact type 

 

 : N/O, CM, N/C

 

 

 

 

   4 Digit Luminous Green (SV)

    Sampling Time                        : 125 msec.

 

    Range 

 

 

  : Refer below table.

    CJC for TC   

 

  : Built in automatic

    

1. DISPLAY TYPE 

 

 : Dual

 

4- Digit

 

7 segment LED

    Resolution   

 

  : 1°C

    LWC for Pt-100 

 

  : Built in up to 18E max.

    Contact Rating 

 

 : 5A @ 250VAC or 30 VDC

    Life expectancy 

 

 : > 5,00,000 operations

3. RELAY OUTPUT

    Isolation 

 

 

 : Inherent

    Isolation 

 

 

 : Non-Isolated.

5. FUNCTION 
    Output 1 

 

 

 : Relay / SSR (Selectable)

    Control Action                      : ON-OFF/PID (Selectable)
    Control Mode                        : Heat/Cool (Selectable)

6. ENVIRONMENTAL

    Storage Humidity 

 

 : 95% Rh (Non-condensing)

    Supply Voltage 

 

 : 90~270VAC, 50/60Hz.

8. PHYSICAL
    Housing 

 

 

 : ABS Plastic.

    Consumption 

 

 : 4W Maximum.

Model no.

Display height (PV)

Display height (SV)

Px-418e

0.39”

0.70”

0.24”

0.50”

Px-718e

Fe-k(J) T/C

Cr-AL(K) T/C

Sensor Type 

Accuracy

  

o

± 1  C

o

-100 ~ 450 C

o

-20.0 ~ 100.0 C

Resolution

Range

o

1  C

o

1  C

}

Pt-100(RTD)

Pt-100(RTD 0.1)

o

760 C

o

-99 

1300 C

o

1  C

o

0.1  C

e

Px-

718

e

Px-

418

(48x48)

(72x72)

o

± 0.3  C