Innovative instruments Px 418e User'S Operating Manual Download Page 2

i

Px-418

e

OVER ALL DIMENSIONS & PANEL CUT OUT (IN MM)

MECHANICAL  INSTALLATION

The label on the controller identifies the serial number, wiring connections and batch number.

INSTALLATION GUIDELINES :

3. Push the controller through panel cut-out and secure 

1. Prepare the cut-out with proper dimension as shown in 

    the controller in its place by tightening the side clamp.

    Figure.      
2. Remove clamp from controller 

 

CAUTION: 

To prevent the risk of electrical shock, switch off the power before making/removing any connection or removing 

the controller from  its enclosure.

ELECTRICAL INSTALLATION :

The electrical connection diagram shown on the controller enclosure is as below.

A

B

D

E

G

F

MODEL:Px-418

e

/718

e

  

PANEL

CUTOUT

Glows when OP1 is ON & flashes when delay time (dly1) is in operation(if selected mode is ON-OFF)

(1) For SP programming. (2) To access Control mode. (3) To access Configuration mode along with UP key. (4) To scroll 
the parameter & to store its value.

(1)  To  increase/alter  parameter  value  in  program  mode.  (2)  To  Enter  in  configuration  mode  (with  SET  key)  .  (3)  To 
acknowledge Alarm. (4) To enter in tune mode (with DOWN Key).

(1) To decrease / alter parameter value in program mode. (2) To enter in tune mode (with    UP Key). 

It will display (1) Measured value of selected input or Error massages in run mode.
(2) Parameters Value in program mode.

It will display (1) SP (Main set point) / SP2 (Auxiliary/Alarm) set value / Set Soak time value/ balance or elapsed soak time 
in run mode. (2) Parameter code in program mode.

1

2

3

4

5

6

7

OP1 LED

UPPER

DISPLAY

LOWER

DISPLAY

SET

KEY

SHIFT

KEY

Sr. 

NAME

FUNCTION

UP

KEY

DOWN

KEY

(2) Press for 3Sec in Programming this will help to go back to previous parameter.

(1) To increase/alter parameter value in program mode with Up / Dn Key.

FRONT PANEL LAYOUT DESCRIPTION :

2

Model no.

Weight (gms.)

Px-418

e

150

230

Px-718

e

OIM Px-X18

e

 V2.1 Page 2 of 5

Px-718

e

TABLE : 1

Model

Dim

A

B

C

D

F

G

E

Px-418

e

Px-718

e

48

72

48

72

3

3

60

70

45

68

45

68

45

68

Px-418

e

FRONT PANEL LAYOUT

Px-718

e

5

7

1

2

3

6

4

4

5

7

1

2

3

6

NO

NC

CM

OP1-RLY

w

w

R

1

2

3

4

5

6

7

14

13

12

11

9

8

15

18

20

19

16

17

 OP1-SSR

10

NO

NC

CM

OP1-SSR

OP1-RLY

1

2

3

4

5

7

8

9

10

6

R

W

W

C

This parameter will be available only if Enabled in Configuration List. 
User can set ramp rate/min for SP1 (Set Point) to minimize overshoot. 

RAMP

RATE

o

 0.0  C

to

o

 25.0  C

User  can  change  SP  value  using  UP/  DOWN  keys.  Holding  the  key,   will 
change  the  value  at  a  faster  rate.  Press  SET  key  to  store  the  desired 
value & move on to the next parameter. 

o

0 C

Disable

LSPL ~ HSPL 

CONTROL

SET

POINT

PROGRAMMING

USER LIST :

 To access the user list press SET key once.

LOWER

DISPLAY

UPPER

DISPLAY

 PARA

METER

RANGE

DESCRIPTION

DEFAULT