10
Installation instructions
After connecting the piping , install the drain hose. Then connect the power cords. After connecting,
wrap the piping, cords and drain hose together with thermal insulation materials.
INNOVAIR DC INVVERTER QUANTUM
SERVICE MANUAL
w w w . i n n o v a i r . c o m
Piping direction
trough
loadin
ece
2
Saw the unloading piece
off along the trough
Note:
When installing the pipe at the directions
1,2 or 4, saw the corresponding unloading piece
off the indoor unit base.
•
Put the piping (liquid and gas pipe) and cables through the wall hole from outside or put them through
from inside after indoor piping and cables connection is complete to connect to the outdoor unit.
•
Decide whether to saw the unloading piece off in accordance with the piping direction.(as shown below)
Indoor unit installation
1. Installing the Mounting Plate
Note: The shape of your mounting plate may be different from the one above, but the installation method is similar.
Note: As the above figure shown, the six holes matched with tapping screw on the mounting plate must be used to
fix the mounting plate, the others are prepared.
3. Indoor Unit Piping Installation
2. Drill a Hole for Piping
•
Decide the position of the hole for piping according to the
location of mounting plate.
•
Drill a hole in the wall. The hole should tilt a little
downward toward outside.
•
Install a sleeve through the wall hole to keep the wall
tidy and clean.
• Decide an installing location for the mounting plate according to the indoor unit location and piping direction.
• Keep the mounting plate horizontal with a horizontal ruler or dropping line.
• Drill holes of 32mm in depth on the wall for fixing the plate.
• Insert the plastic plugs to the hole, fix the mounting plate with tapping screws.
• Inspect if the mounting plate is well fixed. Then drill a hole for piping.