23
results from pressing the FOLLOW ME button on
remote controller, the buzzer will emit a sound and
this indicates the follow me function is initiated.
But when the indoor PCB receives signal which
sent from remote controller every 3 minutes, the
buzzer will not respond. When the unit is running
with follow me function, the PCB will control the
unit according to the temperature from follow me
signal, and the temperature collection function of
room temperature sensor will be shielded, but the
error detective function of room temperature
sensor will be still valid.
2)
When the follow me function is available,
the PCB will control the unit according to the room
temperature from the remote controller and the
setting temperature.
3)
The PCB will take action to the mode
change information from remote controller signal,
but it will not affected by the setting temperature.
4)
When the unit is running with follow me
function, if the PCB doesn’t receive any signal
from remote controller for 7 minutes or pressing
FOLLOW ME button again, the follow me function
will be turned off automatically, and the
temperature will control the unit according to the
room temperature detected from its own room
temperature sensor and setting temperature.
8.4.15 Silence operation(optional)
Press the “silence” button on remote controller to
initiate SILENCE function. When the Silence
function is activated, the compressor running
frequency will keep lower than F2 and the indoor
unit will bring faint breeze, which will reduce the
noise to the lowest level and create a quiet and
comfortable room for you.
8.4.16 Point check function
Press the LED DISPLAY or LED or MUTE button of the remote controller three times, and then press the
AIR DIRECTION or SWING button three times in ten seconds, the buzzer will keep ring for two seconds.
The air conditioner will enter into the information enquiry status. You can press the LED DISPLAY or AIR
DIRECTION button to check the next or front item’s information.
When the AC enter the “information enquiry” status, it will display the code name in 2 seconds, the details
are as follows.
Enquiry information
Displaying code
Meaning
T1
T1
T1 temp.
T2
T2
T2 temp.
T3
T3
T3 temp.
T4
T4
T4 temp.
T2B
Tb
T2B temp.
TP
TP
TP temp.
TH
TH
TH temp.
Targeted Frequency
FT
Targeted Frequency
Actual Frequency
F
r
Actual Frequency
Indoor fan speed
IF
Indoor fan speed
Outdoor fan speed
OF
Outdoor fan speed
EXV opening angle
LA
EXV opening angle
Compressor continuous running time
CT
Compressor continuous
running time
Causes of compressor stop.
ST
Causes of compressor
©2015 Innovair Corporation. All Rights Reserved.