INNOVAIR DC INVERTER NEXXOS
SERVICE MANUAL
w w w . i n n o v a i r . c o m
3.
Electrical parts (Antistatic gloves must be worn.)
Note: Remove the panel plate and fan assembly (refer to 1. Panel plate and 2. Fan assembly) before
disassembling electrical parts.
NIN413C2V32, NIN720C2V32
Procedure
Illustration
1) Remove the connector for the
compressor (see
CJ_ODU_INV_010).
2) Pull out the two blue wires connected
with the four way valve (
CJ_ODU_
INV_010).
3) Pull out connectors of the condenser
coil temp. sensor(T3),outdoor ambient
temp. sensor(T4) and discharge temp.
sensor(TP) (
CJ_ODU_INV_010).
4) Disconnect the electronic expansion
valve wire (
CJ_ODU_INV_010).
5) Then remove the electronic control
box (see
CJ_ODU_INV_010).
CJ_ODU_INV_010
Note: This section is for reference only. Actual unit appearance may vary.
Compressor
T3, T4, TP
Electronic Expansion Valve
Fan motor
4-Way Valve
56