background image

owner’s manual

3

This  manual  does  not  include  Remote  Controller 

Operations,  see  the<<Remote  Controller  Owner's 

manual>> packed with the unit for details. 

Use the system in the following temperature for safe and
effective operation. The Max operation temperature for 
the air conditioner.(Cooling/Heating)

1

If air conditioner is used outside the above conditions, it may 

cause the unit to function abnormally.

The  phenomenon  is  normal  that  the  surface  of  air 

conditioning  may  condense  water  when  the  relative  larger 

humidity in room, please close the door and window.

Optimum  performance  will  be  achieved  within  these 

operating temperature range. 

2

3

3.    AIR CONDITIONER OPERATIONS AND     

       PERFORMANCE

Three-minute protection feature

A  protection  feature  prevents  the  air  conditioner  from  being 

activated for approximately 3 minutes when it restarts immedi-

ately after operation.

Power failure

Power failure during operation will stop the unit completely.

The  OPERATION  lamp  on  the  indoor  unit  will  start  

flashing when power is restored.

To  restart  operation,  push  the  ON/OFF  button  on  the  

remote controller.

Lighting  or  a  car  wireless  telephone  operating  nearby  

may cause the unit to malfunction.

Disconnect the unit with the power and then connect the unit 

with the power again. Push the ON/OFF button on the remote 

controller to restart operation.

4.    HINTS FOR ECONOMICAL OPERATION

Adjust the air flow direction properly to avoid winding toward 

your body.

Adjust the room temperature properly to get a comfortable 

situation and to avoid supercooling and superheat.

 

In cooling, close the curtains to avoid direct sunlight.

To keep cool or warm air in the room, never open doors or 

windows more often than necessary.

Set the timer for the desired operating time.

Never put obstructions near the air outlet or the air inlet. Or it 

will cause lower efficiency, even a sudden stop.

The following should be noticed to ensure an economical operation. 

(Refer to corresponding chapterfor details)

If you don't plan to use the unit for a long time, please discon-

nect power and remove the batteries from the remote control-

ler. When the power switch is connected, some energy will be 

consumed,  even  if  the  air  conditioner  isn't  in  operation.  So 

please  disconnect  the  power  to  save  energy.  And  please 

switch  the  power  on  12  hours  before  you  restart  the  unit  to 

ensure a smooth operation.

A  clogged  air  filter  will  reduce  cooling  or  heating  efficiency, 

please clean it once two weeks.  

NOTE

NOTE

Table 3-1

Table 3-2(for inverter type air conditioner)

Cooling operation

Drying operation

Heating operation

(cooling only type without)

Mode

Temperature

Outdoor
temperature

                            (for the models with low 

                            temperature cooling system)

                            (for special tropical models)

                            (for special tropical models)

temperature

Room

18°C ~ 43°C / 64 °F~109°F        

18°C ~ 52°C / 64 °F~126°F          

-7°C ~ 43°C / 20 °F~109°F

          

-7°C ~ 24°C / 20 °F ~ 76°F          

18°C ~ 43°C / 64 °F~109°F         
18°C ~ 52°C / 64 °F~126°F         

0°C ~ 30°C / 32 °F~86°F

  17°C ~ 32°C

( 62 °F ~ 90°F)

  17°C ~ 32°C

( 62 °F ~ 90°F)

0°C ~ 30°C / 32 °F~86°F

  17°C ~ 32°C

( 62 °F ~ 90°F)

  17°C ~ 32°C

( 62 °F ~ 90°F)

Cooling operation

Drying operation

Heating operation

(cooling only type without)

Mode

Temperature

Outdoor
temperature

                            (for the models with low 

                            temperature cooling system)

temperature

Room

0°C ~ 50°C / 32 °F~122°F          

0°C ~ 50°C / 32 °F~122°F      

-15°C ~ 50°C / 5 °F~122°F 

         

-15°C ~ 24°C / 5 °F~76°F          

FORCED AUTO

The  OPERATION  lamp  is  lit,  and  the  air  conditioner  will  run 

under FORCED AUTO mode. The remote controller operation is 

enabled to operate according to the received signal.

1

FORCED

 

COOL

The  OPERATION  lamp  flashes,  the  air  conditioner  will  turn  to 

FORCED AUTO after it is enforced to cool with a wind speed of 

HIGH  for  30  minutes.  The  remote  controller  operation  is 

disabled.

 

OFF

The  OPERATION  lamp  goes  off.  The  air  conditioner  is  OFF 

while the remote controller operation is enabled.

2

3

For  inverter  type,this  switch  is  used  for  after-sales  service 

purpose only,the user should not push it.

For fixed-frequency type,

this function is used to operate the unit 

temporarily in case you misplace  the  remote  controller  or  its 

batteries  are  exhausted. Two  modes  including 

FORCED 

AUTO  and  FORCED  COOL  can  be selected through the 

TEMPORARY BUTTON on the air-in grill control box of the 

indoor unit. Once you push this button, the air conditioner  will 

run  in  such  order: 

FORCED 

AUTO,  FORCED  COOL, OFF, 

and back to 

FORCED 

AUTO.   

Summary of Contents for IUS0629C21

Page 1: ...loor Type OWNER S MANUAL Thank you very much for purchasing our air conditioner Before using your air conditioner please read this manual carefully and keep it for future reference IUS0629C21 IUS0736C21 IUS0848C21 IUS0852C21 ...

Page 2: ...OOR UNIT OUTDOOR UNIT 1 2 3 5 4 7 6 8 8 8 8 8 8 9 9 7 All the pictures in this manual are for explanation purpose only They may be slightly different from the air conditioner you purchased depend on model The actual shape shall prevail NOTE OR 9 7 8 RESE T TIM E ON TIM E OFF CLO CK SW ING AIR DIRE CTIO N OK ECO SW ING MO DE FAN SPE ED 0 LOCK C H AU TO CO OL DR Y HE AT FAN TEM P SE T CLOC K SET HOU...

Page 3: ...ion systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundeater and get into the food chain damaging your health and well being To prevent refrigerant leak contact your dealer When the system is installed and runs in a small room it is required to keep the concentration of the refrigerant if by any chance coming out below the ...

Page 4: ... supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless th...

Page 5: ...r and remove the batteries from the remote control ler When the power switch is connected some energy will be consumed even if the air conditioner isn t in operation So please disconnect the power to save energy And please switch the power on 12 hours before you restart the unit to ensure a smooth operation A clogged air filter will reduce cooling or heating efficiency please clean it once two wee...

Page 6: ...king efficiency of the air conditioner may greatly decrease Therefore the filter must be cleaned once two weeks during long time usage If the air conditioner is installed in a dust place clean the the air filter frequent If the accumulated dust is too heavy to be cleaned please replace the filter with a new one replaceable air filter is an optional fitting Before you clean the air conditioner be s...

Page 7: ...remely contaminated the temperature distribution inside a room becomes uneven It is necessary to clean the interior of the indoor unit Ask your dealer for details on cleaning the unit This operation requires a qualified service erson When the system is changed over to heating operation after defrost operation Moisture generated by defrost becomes steam and is exhausted A continuous low shah sound ...

Page 8: ...leaks from indoor unit Other malfunctions 8 TROUBLESHOOTING If one of the following malfunctions occur stop operation shut off the power and contact with your dealer If the system does not properly operate except the above mentioned cases or the above mentioned malfunctions is evident investigate the system according to the following procedures See in Table 8 2 8 1 Troubles and causes of air condi...

Page 9: ...locked Doors and windows are open Sunlight directly shine Too much heat resource Outdoor temp is too high Leakage of refrigerant or lack of refrigerant Wait for the comeback of power Switch on the power Replace the fuse Replace the batterises or check the controller Set the temperature properly Wait Check leakage and rightly recharge refrigerant Vacuum and recharge refrigerant Maintenance or chang...

Page 10: ...emote controller is properly directed to the infrared signal receiver of the indoor unit when the ON OFF button is pressed Directly transmit the signal transmitter of the remote controller to the infrared signal receiver of the indoor unit and then repeatly push the ON OFF button twice The indication on the display disappears after a lapse of time Check whether the timer operation has come to an e...