TOUCHPAD AND REMOTE CONTROL

 Set the direction of the air flow

To control the air flow direction

– 

press the 

 key for about 2 seconds

The symbol 

 lit on indicates the constant oscillation of the air flow deflector

To lock the airflow direction again

– 

press again the 

 key

The symbols 

 goes off and the air flow deflector locks in position

Never force the flow deflector manually to move it.

In cooling and dehumidification mode, the flow deflec-
tor’s position is reset every 30 minutes in order to prevent 
the formation of dew.

 Setting the Timer function

For setting the Timer function

– 

press the 

 key for 5 seconds

The symbol 

 on indicates the Timer function enable

This function allows the user to freely program when to 
switch the appliance on or off

To program the activation of the appliance

– 

with thee display off, press the 

 key for 5 seconds

The symbol 

 on indicates the Timer function enable

– 

select with 

 

 the number of hours (from 1 to 24 h) after which the appliance will be switched on automatically

– 

press again the 

 key to confirm the setting

the display lights up in full showing the settings (setpoint, active functions, etc.) that will be activated with the automatic switching 
on of the appliance

– 

press again the 

 key to confirm the setting

To program the stand-by of the appliance

– 

press the 

 key for 5 seconds

The symbol 

 on indicates the Timer function enable

– 

with the arrows 

 

 select the number of hours (from 1 to 24 h) after which the appliance will be automatically turned 

off

– 

press again the 

 key to confirm the setting

the display lights up in full showing the active settings (setpoint, functions, etc.)

– 

press again the 

 key to confirm the setting

 Set the key lock

To set-up the key locking

– 

press the 

 key for 10 seconds

The display lights up in full showing the active settings and the 

 key flashes with a frequency of 1 second

Any action is prevented by the user

To turn off the key-lock

– 

press the 

 key again for 10 seconds

The display lights up in full showing the active settings and the 

 key remains fixed

 Deactivate-put in stand-by the control

To deactivate or put in stand-by the control

– 

press the 

 key for about 2 seconds

The control goes out

The control panel has its own memory, therefore no set-

tings will be lost in case of shut-down or power outage 
(except ventilation).

In stand-by mode, the control guarantees antifreeze pro-
tection.

If you plan to keep the device out of service for a pro-
longed time, remember to deactivate it by disconnecting 
the power or removing the power plug.

Summary of Contents for Filomuro SLW 400

Page 1: ...EN Installation and user manual SLW...

Page 2: ...use of the machine in a rapid unmistakable way Editorial pictograms User Refers to pages containing instructions or information for the user Installer Refers to pages containing instructions or inform...

Page 3: ...rain 14 2 9 Filling the system 15 2 10 Electric connections 15 2 11 Diagrams and configurations electrical controls 17 3 Touchpad and remote control 24 3 1 Interface 24 3 2 Main functions 25 3 3 Warni...

Page 4: ...ost download a copy from the website All repair or maintenance interventions must be per formed by the technical service department or by pro fessionally qualified personnel as foreseen in this bookle...

Page 5: ...al specifications 2 pipes Technical data DC Models m u 400 600 800 Battery water content L 0 50 0 61 0 77 Maximum working pressure bar 10 10 10 Maximum water inlet temperature C 80 80 80 Minimum water...

Page 6: ...during transportation Filomuro Filomuro Filomuro Models m u 400 600 800 Dimensions and weight during transportation Total length mm 1020 1220 1302 Total height mm 490 490 490 Total depth mm 213 213 21...

Page 7: ...all surface is not crossed by pipelines or power lines the wall is perfectly level there are no obstructions nearby that could compromise the inlet and outlet airflow the wall on which you are install...

Page 8: ...A lift the filter slightly rotate until the complete exit from the housing A Filter B Extraction direction A B remove the filter Removal of the aesthetic front panel A side panels B aesthetic front pa...

Page 9: ...stalled later leave the connecting pipes plentiful so as not to make joints A built in cistern B connecting water pipelines C condensation drainage pipe A B C 2 6 Installation use the paper template s...

Page 10: ...en support wall use a leveler check the inclination towards the attachment side fix the screws assemble the unit check correct attachment to the bracket G check the inclination towards the attachment...

Page 11: ...r choosing the right water lines and their size in accordance with good installation practices and the applicable law Keep in mind that undersized pipelines lead to poor sys tem operation Position and...

Page 12: ...ly check that the insulation is tight in order to pre vent the formation and dripping of condensate Hydraulic accessories The device comes standard without any shut off valve In other case depending o...

Page 13: ...ting for water inlet pipe D water outlet pipe fitting E electrical cable entry hole A D E B C Connection with 3 way diverting valve unit with thermoelectric actuator V30688 In case of choice for the 3...

Page 14: ...A Filomuro B liquid drain pipe A B provide a slope never less than 1 insulate fitting points Pay attention to the tilt of the condensate drain pipe Make the condensate liquid flow directly onto a gut...

Page 15: ...etwork are adapted to the absorption of the apparatus considering also any oth er devices in parallel operation the power supply voltage and system frequency match to the values indicated on the devic...

Page 16: ...iring diagram of the unit you are installing You can use a cable embedded in the wall in the position traced with the installation template to make the electrical connection recommended connection for...

Page 17: ...n the supply H2 Water temperature probe M1 Fan motor DC Inverter EV Hot water solenoid valve 230 V 50 Hz 1 A power output L N 230 V 50 Hz electrical power supply connection G Protective conductor CP P...

Page 18: ...spect the AB polarization H2 Hot water temperature probe 10 k M1 Fan motor DC Inverter Y1 Water solenoid valve 230 V 50 Hz 1 A power output L N 230 V 50 Hz electrical power supply connection BO Boiler...

Page 19: ...t the cables unscrew the corresponding screw with a screwdriver remove the conductor When the CP contact opens connected to a clean contact not live the unit is in stand by The display reads CP Error...

Page 20: ...inimum fan speed 680 rpm V4 Super silent speed 400 rpm E Heating cooling selection input Y1 Water solenoid valve 230 V 50 Hz 1 A power output M1 Fan motor DC Inverter TA 3 speed room thermostat to buy...

Page 21: ...nds provided with water probe the on board H2 probe will not be connected the device will be controlled from the remote command If this is not the case connect the 10 k probe located inside the batter...

Page 22: ...suffix 0V00 Printed circuit board BB0699 The PCB is included in the supply L N 230 V 50 Hz electrical power supply 10V Device pilot input 0 10 V Input impedance 25 k Y1 Water solenoid valve 230 V 50...

Page 23: ...value 1400 rmp for voltage values 1 1 V 10 V DC The solenoid valve Y1 is enabled by voltage values 1 V DC turns off with values 0 9 V DC Error signals LED signals LED off The input signal is below 0...

Page 24: ...andle with care avoiding strong impacts or falling on hard surfaces Do not placing obstacles between the remote control and the device while you are using the remote Important If other devices are bei...

Page 25: ...e device can help you locate the switch or introduce a power plug on the device plugging it into the system s socket After you perform these steps you can operate the system either by pressing the sym...

Page 26: ...he set temperature the higher the speed The speed is reduced automatically as the room temperature gradually reaches the set tem perature In dehumidification only mode and night comfort mode you canno...

Page 27: ...ed with the automatic switching on of the appliance press again the key to confirm the setting To program the stand by of the appliance press the key for 5 seconds The symbol on indicates the Timer fu...

Page 28: ...ante Incorrect water temperature In heating mode the water temperature is below 30 C lampeggiante Incorrect water temperature In cooling mode the water temperature is above 20 C Operating the unit if...

Page 29: ...remoted in one of the fan coils connected to it Mounting The wall mounted remote control must be installed on internal walls at a height of about 1 5 m from the floor away from doors or windows away f...

Page 30: ...electric wires through the hole provided fix the base of the control to the wall using suitable screw and plugs perform the electrical connection close the control Pay attention not to crush the cond...

Page 31: ...ence sensor enabling badge remote change of season Function When the contact connected to the CP input is closed all the users connected will be switched off At the touch of a button on the display th...

Page 32: ...y Supervision on Flashing with CP closed contact Switched on for alarm indication Resistance enabled indication Cooling function on Heating function on Remote control indication off Automatic function...

Page 33: ...change The adjustment range goes from 16 to 28 C with a reso lution of 0 5 C Out of range values from 5 C and 40 C are allowed ex cept in automatic mode These value should be set only for short perio...

Page 34: ...use On the display will appear only the room temperature Deactivation To deactivate the display press the key for about 2 seconds All the light signals go off In stand by mode the control ensure an a...

Page 35: ...ol WALL MOUNTED CONTROL B3V151 B3V152 5 1 Electric connections Connection diagram B3V151 1 PCB 2 Wall control H4 H2 S1 N276660C DATA I O LED H4 H2 2 1 B3V152 1 PCB 2 Built in wall control H4 H2 S1 N27...

Page 36: ...amaging the appliance Do not manually move the horizontal louver of the air out let Always use the remote control to do this operation If water leaks from the device you must switch it off im mediatel...

Page 37: ...er B A wash the filter with running water allow it dry Do not use detergents or solvents to clean the filter Inserting the filter Remount the filter paying particular attention to introduce the lower...

Page 38: ...t energy sav ing keep the filters clean keep the doors and windows of the locations fitted with air conditioning systems closed as much as possible During summer limit the entry of direct sun rays int...

Page 39: ...you were to turn on the problem may be in the electronic control The ventilation motor is jammed or burnt Check the motor windings and check if the fan rotates freely The wirings are not correct Chec...

Page 40: ...40 Troubleshooting NOTE...

Page 41: ...41 Troubleshooting NOTE...

Page 42: ...42 Troubleshooting NOTE...

Page 43: ...43 Troubleshooting NOTE...

Page 44: ...realized by Innova technical dept INNOVA S r l Via I Maggio 8 38089 Storo TN ITALY tel 39 0465 670104 fax 39 0465 674965 info innovaenergie com N273110A Rev 06...

Reviews: