Code
Code
Function
Notes
Spit
FIRE
Innotech Systems Inc.
Page 9
22
16h
POWER
23
17h
RECALL
24
18h
TV/VCR
64
40h
PROGRAM
Returns 2, 3 flashes or
error code
65
41h
SOURCE 1
Returns 1 flash
66
42h
SOURCE 2
Returns 1 flash
67
43h
SOURCE 3
Returns 1 flash
68
44h
SOURCE 4
Returns 1 flash
80
50h
Transmit IR continuously
until told to stop
(Return 0 flashes)
81
51h
Transmit IR once
(Return 1 flash)
82
52h
Transmit IR twice
(Return 2 flashes)
83
53h
Transmit IR three times
(Return 3 flashes)
84
54h
Transmit IR four times
(Return 4 flashes)
85
55h
Transmit IR five times
(Return 5 flashes)
86
56h
Transmit IR six times
(Return 6 flashes)
87
57h
Transmit IR seven times
(Return 7 flashes)
88
58h
Transmit IR eight times
(Return 8 flashes)
89
59h
SEARCH (AutoSearch)
90
5Ah
Toggle Punch-through
(Return 1 flash [on] or
0 flash [off])
96
60h
Return firmware major
(Returns 1 flash)
97
61h
Return firmware minor
(Returns 1 flash)
98
62h
Return database revision
major
(Returns 1 flash)
99
63h
Return database revision
minor
(Returns 1 flash)
Source is used to identify the device being controlled (TV, VCR, Cable etc).
Spit
FIRE
Innotech Systems Inc.
Page 10
DEVICE SET UP
Before any IR messages can be sent, the Spit
FIRE
must be programmed
with the type of appliance is being controlled. The Spit
FIRE
provides three
programming modes: manual, manual search and automatic search.
Manual Programming
The programming sequence is as follows:
‚
Source
‚
PROGRAM
‚
3-digit-ISI-number
‚
PROGRAM
The Spit
FIRE
includes a visible front panel LED that will flash to indicate
the progress of the programming sequence. The visible LED flash informa-
tion is also returned as a status byte to help the host track its progress
through the programming sequence.
The ISI number is a three digit code that indicates which type of device is
being controlled. Innotech provides a list of ISI-to-manufacturer types.
Leading zeros must be included in the programming sequence. For exam-
ple, to set up the VCR whose ISI number is 045, the “virtual key” sequence
is:
Button
LED Flashes
Source 1
1
PROGRAM
2
#0
1
#4
1
#5
1
PROGRAM
3
For hand held remote controls this button sequence is inherently a button
press followed by a button release. For the Spit
FIRE
, the system must send